"Redlion 1003GX2-B" - это продукт с железной инструкцией, которую вы можете бесплатно загрузить с нашего веб-сайта. Этот Hardware Manual поможет вам разобраться с функциями этого устройства. Скачивайте бесплатно с manualshive.com.
N-Tron
®
Series 1000
Industrial Gigabit Media Converters
& Gigabit Ethernet Switches
Hardware Guide | August 2016
Страница 1: ...N Tron Series 1000 Industrial Gigabit Media Converters Gigabit Ethernet Switches Hardware Guide August 2016 ...
Страница 2: ...a particular purpose In no event shall Red Lion be liable for any incidental special indirect or consequential damages whatsoever included but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein CONTACT INFORMATION AMERICAS Inside US 1 877 432 9908 Outside US 1 717 767 6511 Hours 8am 6pm Eastern Standard Time UTC GMT 5 hours ASIA PACIFI...
Страница 3: ...iv Warnings and Cautions v General Safety Cautions and Warnings v Electrical Safety Warnings v Environmental Safety Cautions and Warnings vii Hazardous Location Warning vii Laser Safety Warning viii Section 1 Introduction and Specifications Introduction 1 1 Key Features 1 1 Model 1002MC 1 2 Key Specifications 1 2 Dimensions 1 3 Product Ordering Guide 1 4 Model 1002MC Regulatory Approvals 1 4 Warra...
Страница 4: ... Regulatory Approvals 1 16 Warranty 1 16 Section 2 Installation Introduction 2 17 Unpacking 2 17 Inspection 2 17 Installing Mounting 2 17 DIN Rail Mounting 2 18 Connections 2 19 Power Connection Top View 2 19 Ground Connection 2 19 N Tron Series Switch Grounding Techniques for 1000 Series 2 19 RJ45 Connector Crimp Specifications 2 21 Cable Connection 2 21 Section 3 Operation and Maintenance Introd...
Страница 5: ...the FCC Rules This product complies with Part 15 of the FCC A Rules Operation is subject to the following conditions 1 This device may not cause harmful Interference 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the F...
Страница 6: ...ument and all product updates can be accessed through the Red Lion web site at http www redlion net documentation Publication History The following information lists the release history of this document ISSUE REVISION RELEASE DATE CONTENT DESCRIPTION Revised 2014 01 23 January 2014 Document Updates Revised 2015 03 17 March 2015 Added 1008TX Model Format Changes Revised 2015 03 24 March 2015 Format...
Страница 7: ...o do so Do not substitute unauthorized parts or make unauthorized modifications to the unit ATTENTION Ne pas effectuer de services sur l appareil s il n est pas qualifié pour le faire Ne pas substituer pièces non autorisées ou de modifications non autorisées de l appareil CAUTION Do not operate the equipment in a manner not specified by this manual ATTENTION Ne pas faire fonctionner l équipement d...
Страница 8: ... A Recognized or Listed fuse rated maximum 3A minimum 30VDC must be installed on the line side of the device ALERTE Un fusible reconnu ou classé classé 3A maximale 30VDC minimum doit être installé sur le côté de la ligne de l appareil WARNING Use 110 C or higher rated copper wire 0 22Nm 2 lb in tightening torque for field installed conductors ALERTE Utilisez 110 C ou nominale supérieure fil de cui...
Страница 9: ...utes avant de la toucher Hazardous Location Warning WARNING 1005TX 1008TX and 1008TX POE only This equipment is open type device and is meant to be installed in an enclosure suitable for the environment that is only accessible with the use of a tool ALERTE 1005TX 1008TX and 1008 TXPOE uniquement Cet équipement est ouvert de type périphérique et est destiné à être installé dans un boîtier adapté à ...
Страница 10: ...LP1001 viii N Tron Series 1000 Hardware Guide Laser Safety Warning CAUTION 1002MC and 1003GX2 only CLASS 1 LASER PRODUCT Do not stare into the laser ATTENTION 1002MC et 1003GX2 uniquement PRODUIT LASER CLASSE 1 Ne pas regarder dans le laser ...
Страница 11: ...ve 10 100 1000Base T copper ports The 1008TX is an eight port unmanaged Gigabit switch that offers eight 10 100 1000Base T copper ports The 1008TX POE is an eight port unmanaged Gigabit switch that offers eight 10 100 1000Base T copper ports including 4 PoE capable ports up to 30 Watts each Red Lion s industrial Power over Ethernet PoE solutions are designed to transmit power and data over an Ethe...
Страница 12: ...AL Height 4 0 in 10 16 cm Input Voltage 10 30 VDC Regulated Width 1 0 in 2 54 cm Input Current 200mA max 24VDC Steady State Depth w typical SFP installed 3 6 in 9 165 cm Inrush Current 13 Amp 0 8 ms max 24VDC Weight 0 7 lbs 0 32 kg Input Ripple Less than 100 mV DIN Rail 35 mm Input Wire Size 12 24 AWG BTU hr 16 4 ENVIRONMENTAL NETWORK MEDIA Operating Temperature 40 C to 85 C 10BaseT Cat 3 Storage ...
Страница 13: ... Max 17dBm 20dBm 22dBm 24dBm Wavelength 850nm 1310nm 1310nm 1550nm Laser Type VCSEL FP DFB DFB Fiber length distances represent technical performance Link budgets should be evaluated based on specific application conditions Gigabit Fiber Transceiver SFP Characteristics Dimensions LNK ACT SPD 1000 10 100 1000Base T RX TX ACT LNK 1000Base SX LX 1002MC 3 85 97 77mm 1 20 30 42mm 3 85 97 71mm 3 61 91 6...
Страница 14: ...Hardware Guide Product Ordering Guide Model 1002MC Regulatory Approvals Safety For use in Class I Division 2 Groups A B C and D Hazardous Locations UL 508 Industrial Control Equipment ANSI ISA 12 12 01 2007 for use in Class I and II Division 2 and Class III Divisions 1 and 2 Hazardous Classified Locations Groups A B C D T4A cUL C22 2 No 14 M05 cUL C22 2 No 213 M1987 for use in Class I Division 2 H...
Страница 15: ...rs The 1003GX2 LX 10 has one 10 100 1000BaseT port and two 2 1000BaseLX 10 SFP transceivers The 1003GX2 LX 40 has one 10 100 1000BaseT port and two 2 1000BaseLX 40 SFP transceivers The 1003GX2 LX 80 has one 10 100 1000BaseT port and two 2 1000BaseLX 80 SFP transceivers Key Specifications Table 3 1003GX2 Key Specifications PHYSICAL ELECTRICAL Height 4 0 in 10 16 cm Input Voltage 10 30 VDC Regulated...
Страница 16: ...P LX 10 NTSFP LX 40 NTSFP LX 80 Fiber Length 550m with 50 125µm 275m 62 5 125μm 10km 40km 80km TX Power Min 9 5dBm 9 5dBm 2dBm 0dBm RX Sensitivity Max 17dBm 20dBm 22dBm 24dBm Wavelength 850nm 1310nm 1310nm 1550nm Laser Type VCSEL FP DFB DFB Fiber length distances represent technical performance Link budgets should be evaluated based on specific application conditions Dimensions ...
Страница 17: ... LX ZZ One 1000BaseSX Singlemode SFP Gigabit Transceiver two required per unit Note Unit must be populated with two SFP transceivers upon shipment N Tron Series 1000 Hardware Guide 1 7 Introduction and Specifications Revised 2016 08 30 Drawing No LP1001 Product Ordering Guide ZZ 10 40 or 80 for GB Singlemode SFP Transceiver Model 1003GX2 Regulatory Approvals Safety For use in Class I Division 2 Gr...
Страница 18: ...ommunication requirements while providing high throughput and minimum downtime Key Specifications Table 5 PHYSICAL ELECTRICAL Height 4 0 in 10 16 cm Input Voltage 10 30 VDC Regulated Width 1 0 in 2 54 cm Input Current 230mA max 24VDC Steady State Depth 3 6 in 9 165 cm Inrush Current 13 Amp 0 6 ms max 24VDC Weight 0 7 lbs 0 32 kg Input Ripple Less than 100 mV DIN Rail 35 mm Input Wire Size 12 24 AW...
Страница 19: ...roduction and Specifications Revised 2016 08 30 Drawing No LP1001 Dimensions Part Number Application 1005TX Five port 10 100 1000BaseT Ethernet switch 1000 PM Panel Mount kit NTPS 24 1 3 DIN Rail Power Supply 24V 1 3 Amp Product Ordering Guide ...
Страница 20: ...sion 2 and Class III Divisions 1 and 2 Hazardous Classified Locations Groups A B C D T4 cUL C22 2 No 14 13 Industrial Control Equipment cUL C22 2 No 213 15 for use in Class I and II Division 2 and Class III Divisions 1 and 2 Hazardous Classified Locations EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4...
Страница 21: ...n 11 76 cm Input Voltage 10 49 VDC Regulated Width 1 5 in 3 94 cm Input Current 250mA max 24VDC Steady State Depth 4 0 in 10 37 cm Inrush Current 20 Amp 0 06 ms max 24VDC Weight 0 7 lbs 0 32 kg Input Ripple Less than 100 mV DIN Rail 35 mm Input Wire Size 12 24 AWG BTU hr 20 5 ENVIRONMENTAL NETWORK MEDIA Operating Temperature 40 C to 85 C 10BaseT Cat 3 Storage Temperature 40 C to 85 C 100BaseT Cat ...
Страница 22: ...Revised 2016 08 30 Introduction and Specifications Drawing Number LP1001 1 12 N Tron Series 1000 Hardware Guide Dimensions ...
Страница 23: ...ardous Locations UL 508 Industrial Control Equipment ANSI ISA 12 12 01 2015 for use in Class I and II Division 2 and Class III Divisions 1 and 2 Hazardous Classified Locations Groups A B C D T4 cUL C22 2 No 14 13 Industrial Control equipment cUL C22 2 No 213 15 for use in Class I Division 2 and Class III Divisions 1 and 2 Hazardous Classified Locations EMI FCC Title 47 Part 15 Subpart B Class A In...
Страница 24: ... Voltage 22 49 VDC Regulated Width 2 0 in 5 11 cm Input Current 5 6A max 24VDC Under Full Load Depth 5 9 in 15 04 cm Inrush Current 70 5 Amp 60us 24VDC Weight 1 5 lbs 0 69 kg Input Ripple Less than 100 mV DIN Rail 35 mm Input Wire Size 12 16 AWG BTU hr 60 ENVIRONMENTAL NETWORK MEDIA Operating Temperature 40 C to 80 C 10BaseT Cat 3 Storage Temperature 40 C to 85 C 100BaseT Cat 5 Operating Humidity ...
Страница 25: ...N Tron Series 1000 Hardware Guide 1 15 Introduction and Specifications Revised 2016 08 30 Drawing No LP1001 Dimensions ...
Страница 26: ...provals Safety ANSI ISA 12 12 01 2015 Class I and II Div 2 and Class III Div 1 and 2 Groups A B C and D Hazardous Locations T4 UL508 Industrial Control Equipment CAN CSA C22 2 No 213 15 Hazardous Locations CAN CSA C22 2 No 14 13 Industrial Control Equipment EMI FCC Title 47 Part 15 Radio Frequency Devices Subpart B ANSI C63 4 2009 Industry Canada ICES 003 EN 55032 EN 61000 3 2 EN61000 3 3 EMC EN 5...
Страница 27: ... Media Converter or Ethernet Switch 2 Product CD If the package contents are damaged 1 Contact your carrier 2 File any damage claims with the carrier Installing Mounting Read the following warning before beginning the installation Lire l avertissement suivant avant de commencer l installation WARNING Never install or work on electrical equipment or cabling during periods of lightning activity Neve...
Страница 28: ...d to mount the 1000 Series enclosures to standard 19 racks and our Panel Mount Assembly P N 1000 PM can be used to mount the 1000 Series enclosures to a panel or any other flat surface The 1008TX POE will require the 1K26 PMK panel mount b To install the unit to 35mm industrial DIN Rail place the top edge of the included mounting bracket on the back of the unit against the DIN Rail at a 15 angle a...
Страница 29: ...ed to separate DC Voltage sources Use wire sizes of 12 24 gauge for non PoE models and 12 16 gauge for PoE models Limit the power cord length to less than 10 meters in order to ensure optimum performance Recommend using 24V DC Power Supplies similar to 100 240VAC N Tron NTPS 24 1 3 DC 24V 1 3A 100 240VAC N Tron NTPS 48 5 DC 48 5A Ground Connection 100 240VAC N Tron NTPS 24 10 DC 24V 10A Ground Con...
Страница 30: ...ifications are required for use with N Tron series switches In the event all Cat5e patch cable distances are small i e All Ethernet devices are located the same local cabinet and or referenced to the same earth ground it is permissible to use fully shielded cables terminated to chassis ground at both ends in systems void of low level analog signals Users may run a drain wire lug from the screw pro...
Страница 31: ...ter twisted pair cable into the RJ45 connector Connect the other end to the far end station The total length should not exceed 100 meters 3 Verify that the LNK ACT LEDs are ON once the connection has been completed 4 To connect any other port to another Switch or Repeater use a standard Cat5e straight through or crossover cable CAUTION Creating a port to port connection on the same switch i e loop...
Страница 32: ...ustrial Gigabit Ethernet Switch devices provide operating status information through the LED indicators located on the front panel Controls and Indicators Model 1002MC 1003GX2 1005TX Indicators Table 8 INDICATOR DESCRIPTION Green LED lights when power is connected LED indicating link activity LED indicating 1000 Link data speed Model 1002MC 1003GX2 1005TX Indicators from top to bottom LNK ACT SPD1...
Страница 33: ...o link activity on cable ON Link is operating at 1000Mbps OFF Link is operating at 10 100Mbps Model 1002MC 1003GX2 1005TX Indicator States Model 1008TX Indicators Table 10 Model 1008TX Indicators from top to bottom INDICATOR DESCRIPTION Green LED lights when power is connected LED indicating activity LED indicating 1000 Link data speed Table 11 describes the indicator states and the operating mode...
Страница 34: ...ctivity on cable OFF No link activity on cable ON Link is operating at 1000Mbps OFF Link is operating at 10 100Mbps Model 1008TX POE Indicators Table 12 INDICATOR DESCRIPTION V1 Power LED V2 Power LED Power Supply PoE activity LED indicating activity LED indicating 1000 Link data speed Model 1008TX POE Indicators from top to bottom Table 13 describes the indicator states and the operating modes AC...
Страница 35: ...PoE power is being applied to the corresponding port OFF No PoE power is being applied to the corresponding port Model 1008TX POE Indicator States Maintenance Maintenance is limited to verifying the cable interface and unit cleaning Verify Troubleshoot Cable Interface 1 Make sure the Power LED is ON 2 Make sure you are supplying sufficient current for the chosen switch version Note The inrush curr...
Страница 36: ...RSE OF PERFORMANCE USAGE OF TRADE OR OTHERWISE Customer shall be responsible for determining that a Product is suitable for Customer s use and that such use complies with any applicable local state or federal law b The Company shall not be liable for a breach of the warranty set forth in paragraph a if i the defect is a result of Customer s failure to store install commission or maintain the Produ...