5.3
Status Code Definitions
The status code is displayed in a series of hexadecimal characters representing the
status of different alarm conditions. The value '1' indicates the associated condition is
active. All unused bits are set to zero.
To determine the status, the hexadecimal number must be converted to binary notation.
It is recommended to use a scientific calculator that supports binary notation (e.g.,
Windows on-screen calculator). Set the mode for Hex and enter the status code.
Change the mode to binary and match active bits (1) to the PMP Status Codes table.
Table 21
:
Diag. - Status Code Bits (Binary/Hex)
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0
0
0
0
0
0
0
0
Table 22
:
Diag. - Status Codes
Bit
Hex Display*
Description
1
0000 0002
Radio over-temperature
2 - 3
Not used
4
5
6
0000 0010
0000 0020
0000 0040
PLL Errors
7
Not used
8
0000 0100
Firmware Error
9 - 15
Not used
16
0001 0000
No Ethernet packets received by the wireless MAC
17
18
19
20
21
22
23
24
25
26
27
28
0002 0000
0004 0000
0008 0000
0010 0000
0020 0000
0040 0000
0080 0000
0100 0000
0200 0000
0400 0000
0800 0000
1000 0000
MAC Internal Errors
29-31
Not used
*Displayed error code value if this is the only error present.