www.altronics.com.au
Redback® Proudly Made In Australia 25
Redback® A 4480B
8 In to 8 Out Audio Switcher
The consoles are connected to the A 4480B via standard Cat5e cabling as shown in Fig 5.1B. The maximum distance
between the A 4480B and a paging console is 300m. Note that each paging console must be assigned an ID number
before operation (see section 5.1.2 DIP switch settings).
A maximum of eight consoles can be connected at one time but only used in certain configurations. There are four RJ45
ports on the back of the A 4480B which can be used to connect the A 4481 paging consoles. Each port can accomodate a
maximum of two paging consoles. Fig 5.1B shows how to connect one paging console per RJ45 port.
5.1.4 Cascading the paging consoles
If more than four paging consoles are required the consoles can be cascaded together with the addition of external power
supplies. Fig 5.1C shows how to connect eight paging consoles at once. In this fig consoles 1-2 are connected to Port 1,
consoles 3-4 to port 2, consoles 5-6 to port 3 and consoles 7-8 are connected to Port 4. Please note: A maximum of 2
paging consoles can be connected per RJ45 port on the A 4480B. Each additional paging console has a dedicated power
supply and the total cat5 cable run can be no longer than 300m. I.e the maximum length of cable (after all paging
consoles have been cascaded) to the furthest paging console is 300 metres.
Fig 5.1C
Peripheral Connections
Output levels
Voice Chime Alert
Over
& Evac
24VDC In
(4A M205)
Lift/Chassis
ZONE PLATES OR PRESET PLATE
Keyboard
INPUTS
SW2
SW1
8
7
6
5
4
3
2
1
Vox
Level
Volume
Priority Input
L
R
Vox
Level
Trigger
To Paging Consoles/Preset Plate
3
4
1 2 3 4
ALERT - EVACUATION MODULE
1 2 3 4
L
R
SW3
EV
CO
M
CH1/ C
AN
CH2
AL
2 - Hot
1 - Shield
2 - Hot
3 - Cold
2
1
3
SW3 Input 1 & 2 XLR
Phantom Power Settings
SW
ON OFF
(1) Input 1
ON OFF
(2) Input 2 ON OFF
Triggers
OUTPUT
S
8
7
6
5
4
3
2
1
EMERGENCY INPUT
DC Fuse
Earth Lift
+
-
24VDC In
Power Fail
+
_
Manufactured in Australia By
Altronic Distributors Pty. Ltd.
www.redbackaudio.com.au
BCD & DIP SWITCH SETTINGS
DIP SWITCH
CHIME CONTACT
4
5
6
7
CH2
CH1/CANCEL
OFF OFF OFF OFF
Pre Announce
Ding Dong
ON OFF OFF OFF
Pre Announce Repeating Bong
OFF ON OFF OFF
Pre Announce Repeating Bing
OFF OFF ON OFF
Pre Announce
CANCEL
OFF OFF OFF ON
Ding Dong
Pre Announce
ON
ON
ON
ON
Ding Dong
Repeating Bong
OFF ON
ON
ON
Ding Dong
Repeating Bing
ON OFF ON
ON
Ding Dong
CANCEL
ON
ON OFF ON
Repeating Bong Pre Announce
ON
ON
ON OFF Repeating Bong
Ding Dong
OFF OFF ON
ON
Repeating Bong Repeating Bing
OFF ON OFF ON
Repeating Bong
CANCEL
OFF ON
ON OFF
Repeating Bing Pre Announce
ON
ON OFF OFF
Repeating Bing
Ding Dong
ON OFF ON OFF
Repeating Bing Repeating Bong
ON OFF OFF ON
Repeating Bing
CANCEL
The Alert/Evacuation module has multiple chime options, a recordable
voice-over message and adjustable alert to evacuation tone switch-over times.
These options are selectable inside the unit, via the BCD rotary switch and
DIP switches located on the alert/evacuation module (refer to below settings).
ON
OFF
Momentary Alert
& Evac operation
Latched Alert
& Evac operation
1
2
3
4
Voice-over
message ON
Voice-over
message OFF
Not Used
Not Used
Mic recording
enabled
Mic recording
disabled
DIP
SW
1 2 3 4
SW5
1
2
(Maximum 500mA per output)
8
7
6
5
4
3
1
SW4
(Not Used)
16GB
Maximum
Micro SD Card
2
1 2
3
4
1 2
3
4
1 2
3
4
1 2
3
4
1 2
3
4
Aux Input Sensitivity
DIP Switch Settings
SW1
ON OFF
(1) Input 1 0.3V 0.7V
(2) Input 2 0.3V 0.7V
(3) Input 3 0.3V 0.7V
(4) Input 4 0.3V 0.7V
SW2
ON OFF
(1) Input 5 0.3V 0.7V
(2) Input 6 0.3V 0.7V
(3) Input 7 0.3V 0.7V
(4) Input 8 0.3V 0.7V
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
Max 300m
Max 300m
Max 300m
Max 300m
M 8968C 24V DC 1A
Power Supply
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
M 8968C 24V DC 1A
Power Supply
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
M 8968C 24V DC 1A
Power Supply
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
Store
Recall
All Call
Emergency
(All Zones)
A 4481 Communicator
System Busy
Page
Lock On
REDBACK
A 4481
8 Zone Communicator
Version 1.1
Cancel
M 8968C 24V DC 1A
Power Supply
CONSOLE 1
ID = 1
CONSOLE 5
ID = 5
CONSOLE 2
ID = 2
CONSOLE 6
ID = 6
CONSOLE 8
ID = 8
CONSOLE 4
ID = 4
CONSOLE 7
ID = 7
CONSOLE 3
ID = 3