Fig 1.4A

 shows the layout of the A 4567B front panel.

Fig 1.4A

Zone Indicators

 

These LED’s indicate the status of each of the 10 zones. 

2  

Zone Status Indicator Legend

 

The legend outlines the status of the 10 zones. Green indicates a “Normal” condition on the zone. Orange  

 

indicates an “Open” condition on the zone. i.e. the speaker line has a break somewhere on the line. Red  

 

indicates a “Short” condition. i.e. there is a short circuit on the line.

3 Buzzer

 

The buzzer sounds when either an “Open” or a “Short” condition occurs on a zone.

Cancel Buzzer Button

 

This button is used to cancel the buzzer from sounding. Note: This does not turn off the fault indicator/s.

On indicator

 

Indicates when the unit has power. 

Power Switch

 

Used to turn on the unit. Note: The 24V DC backup input bypasses the power switch.

1.4 FRONT PANEL GUIDE

Overview

Power

Zone 1

Line Monitoring Unit

A 4567B

Zone 2

Zone 3

Zone 4

Zone 5

Zone 6

Zone 7

Zone 8

Zone 9

Zone 10

Status  

Cancel

Buzzer

Normal
Open
Short

On

2

3

4

5

6

1

Содержание A 4567B

Страница 1: ...1300 780 999 Fax 1300 790 999 Internet www altronics com au IMPORTANT NOTE Please read these instructions carefully from front to back prior to installation They include important setup instructions F...

Страница 2: ...ur LED indicates line condition accordingly for each zone Internal audible alarm buzzer with cancel button is fitted With any fault condition a switched output is provided for remote monitoring purpos...

Страница 3: ...Red indicates a Short condition i e there is a short circuit on the line 3 Buzzer The buzzer sounds when either an Open or a Short condition occurs on a zone 4 Cancel Buzzer Button This button is used...

Страница 4: ...n the N O and ground terminals when this output is activated When this output is not active 24V appears between the N C and ground terminals 7 Short 24V Output This is a 24V DC output which is activat...

Страница 5: ...the end of the lines and all speakers must have 22uF Bipolar caps fitted See Fig 2 2 for more details NOTE The maximum wire run is 200 metres An A 4568 Fire Indicator Board Interface has been connecte...

Страница 6: ...peaker line going out of speaker termination Loop Out End of Line resistor 100K 0 25W Speaker line coming into speaker termination Loop In Fig 2 2b Fig 2 2c Fig 2 2d Fig 2 2a shows an Altronics C 2168...

Страница 7: ...or Short condition on any zone The terminals provided can be used for Normal or Failsafe modes The output terminals have a N O normally open N C normally closed and a ground connection In this configu...

Страница 8: ...NECTORS Open 24V DC Out Screw Terminals Short 24V DC Out Screw Terminals Combined 24V DC Out Screw Terminals INPUT CONNECTORS 24V DC Power Screw Terminals Zone connections Screw Terminals CONTROLS Can...

Отзывы: