Redback A 1708 Скачать руководство пользователя страница 4

Redback® Proudly Made In Australia

4

Enter

Manual Selection Screen

OUTPUT 1

[AUTO]  ON   OFF

OUTPUT 1

AUTO  [ON]   OFF

OUTPUT 1

AUTO  ON   [OFF]

1) Manual select           

 of output zones

OUTPUT 2

[AUTO]  ON   OFF

OUTPUT 2

AUTO  [ON]   OFF

OUTPUT 2

AUTO  ON   [OFF]

OUTPUT 3

[AUTO]  ON   OFF

OUTPUT 3

AUTO  [ON]   OFF

OUTPUT 3

AUTO  ON   [OFF]

OUTPUT 4

[AUTO]  ON   OFF

OUTPUT 4

AUTO  [ON]   OFF

OUTPUT 4

AUTO  ON   [OFF]

Exit Manual

Zone Selection

Press the UP and DOWN

buttons to scroll up and 

down.

Enter

Press the ENTER

button to make your

selection

Menu

Press the MENU

button to exit at any 

time.

Fig 3.5

SPECIAL NOTE FOR FIRST TIME USE: 

When powering up the unit for the first time it will be necessary to 

clear the memory before entering any Station (Event) times. If this is not 

done the unit will not operate correctly. To do this use option 4 in the 

menu. Refer to the section on “Clearing the Memory”.

Navigate to the “Add or Edit a Station Time” Sub Menu as shown in Fig 3.3. If this is the first time entering this menu the 
screen should appear as shown in Fig 3.6. The number “1)” shown is the Station (or Event) number which is highlighted 
by a flashing cursor.

3.1.2 Add or Edit A Station  Time

This option allows the user to enter the Station (Event ) information which includes the event “Turn on time”, “Duration” 
and “Output Zone”.

If this is the first time an Event has been entered the memory will need to be “Cleared” first. To do this follow the 
directions in the section “Clearing the Memory”.

1)   -  DAY           

 Start @ 00:00:00

Fig 3.6

To set a Zone manually, scroll to the desired zone using the up and down buttons as shown in Fig 3.5 and then press 
“Enter” when you reach your selection. When finished scroll to the “Exit Manual Zone Selection” screen and press 
“Enter” or press the “Menu” button to exit at any time.  (NOTE: For the unit to continue in “AUTO MODE” you must exit 
back to the Main Screen.)

SPECIAL NOTE:

If power is removed, all outputs will switch off and all zones will

return to Auto mode once power is restored.

Содержание A 1708

Страница 1: ...tput 24 Hour 7 day Timer Redback Proudly Made In Australia IMPORTANT NOTE Please read these instructions carefully from front to back prior to installation They include important setup instructions Fa...

Страница 2: ...ill become active and 24V DC will be present at the terminals At the same time the closing contact for that zone will short and stay that way until the zone is again set OFF NOTE the 24V DC outputs sw...

Страница 3: ...Manual Select of Output Zones Screen This is the first of 5 sub menu screens which are navigated by pressing the up and down buttons as shown in Fig 3 3 Pressing the Menu button again will return the...

Страница 4: ...a Station Time Sub Menu as shown in Fig 3 3 If this is the first time entering this menu the screen should appear as shown in Fig 3 6 The number 1 shown is the Station or Event number which is highli...

Страница 5: ...the day of the week that the Event will take place and can be any day from Monday to Sunday or one of many multiple day options which are listed below Pressing the up and down buttons will scroll thr...

Страница 6: ...ure again to change the seconds and press Enter when finished The start time is now set for this Station or Event After completing the start time the screen will change to the Zone and Duration option...

Страница 7: ...our by pressing the 10 up and down buttons and press Enter when finished The cursor will now move to the minute section of the duration Repeat the above procedure to change the minutes and press Enter...

Страница 8: ...0 Edit Press the 10 button to change the hour min secs 10 Press the UP and DOWN buttons to change the day Enter Press the ENTER button to make your selection Menu Press the MENU button to exit at any...

Страница 9: ...hed off when adjusting DIP switches New settings will be effective when power is switched back on 4 0 DIP SWITCH SETTINGS There are four DIP switches accessible on the rear of the A 1708 which are for...

Страница 10: ...r Memory Mode will be restricted Therefore there can be no erasing of the Station Event times stored in memory 6 0 REAR CONNECTIONS 6 1 24V DC Connectors DC sockets have been provided for 24V DC input...

Страница 11: ...closing contact of the timer is connected to the Input 1 trigger of the message player When Zone 2 is activated by the timer message 1 of the message player will be played 4 L R Line Out 12 30V DC Sw...

Страница 12: ...ME 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 7 0 EVENT TIMES RECO...

Отзывы: