RedBack Lasers EL614 Скачать руководство пользователя страница 10

10

www.redbacklasers.com.au

Setting Grades 

(requires remote control that comes with Grade & Grade +MM kits)

EL614

TM 

OPERATING INSTRUCTIONS cont.

The EL614 Grade and Grade + MM kits come with a remote control that 

can set a grade on one axis, it can be set to either the “X” or “Y” axis but 

not both.

First set up the laser aligning the X axis with the direction of the required 

grade rise/fall, the laser can be placed anywhere on site as long as the X 

axis runs parallel or in line with the desired grade.

For this example we want a grade of 1 in 60 or 1.667% or in other words 

for every 6m (6000mm) travelled away from the laser along the X axis we 

want the laser plain to tilt down/up 0.1m (100mm).

To achieve this measure out 6m away from the laser along the X axis and 

hold the staff at this point slide the receiver up/down the staff until the 

receiver indicates level.

Then making a note of the height on the staff slide the receiver up/down 

the staff 100mm from the level point, this is now the height the laser needs 

to be hitting to be setting a 1 in 60 slope or grade.

Using the remote, select grade mode on the X axis and use the Slope Grade 

Direction buttons  to slope the laser until the receiver shows level (see page 

6 for remote diagram).

The Grade is now set at 1 in 60 or 1.667% on the X axis and anywhere on 

or parallel to the X axis on site.

Содержание EL614

Страница 1: ......

Страница 2: ...ly into laser beam Do not disassemble the instrument or attempt to perform any internal servicing Repairs and service should be performed only authorised service centres of Redback Lasers This instrum...

Страница 3: ...and Wind setting control allows you to continue to work in high wind or on sites close to machinery If you have purchased your EL614 with Remote then there is also a single grade match feature The EL...

Страница 4: ...4 EL614TM DIAGRAMS EL614TM Laser Unit 1 2 3 1 Laser Output Window 2 Rubberised Casing 3 Keypad 4 Battery Compartment www redbacklasers com au 4 EL614TM Safety Cage...

Страница 5: ...Mode Speaker Control Power On Off Rubber Casing LCD Display Repeated on rear Bubble Vial Display back light Power On Off Tilt On Off Rotation Speed Vibration Wind Sensor Select Axis LED s For Grade Se...

Страница 6: ...Settings Remote Control Grade Setting Grade Grade mm Kits only TILT and V W S buttons as per main control panel page 9 Grade Setting Functions Left button selects axis Right buttons slope up or down a...

Страница 7: ...e battery pack Handy Hints Prior to initial use charge the rechargeable batteries for at least 8 hours Running rechargeable batteries completely flat will increase battery life The EL614 can operate o...

Страница 8: ...l Tilt stop working and the laser beams will flash to indicate this You will need to then re level the laser by pressing the tilt button note that the tilt is then disabled to re enable press the TILT...

Страница 9: ...ver when being used at different distances from the laser For most situations the default speed 800rpm will provide best results V W S Vibration Wind Sensor Setting The EL614 continuously self levels...

Страница 10: ...every 6m 6000mm travelled away from the laser along the X axis we want the laser plain to tilt down up 0 1m 100mm To achieve this measure out 6m away from the laser along the X axis and hold the staf...

Страница 11: ...press shows no symbol on the LCD and allows 3mm before showing off level these two coarser modes are more suitable for general site levelling The Back Light button toggles the LCD display back light...

Страница 12: ...king the long reception window on the front of the receiver When displaying the height of the laser compared to the level point in mm the LR720 will display up to 45mm from level between 45mm and 65mm...

Страница 13: ...on the casing A custom level point can be set between 20mm above and 20mm below the default level point A custom level point is set to where the laser is currently striking assuming it is within the...

Страница 14: ...to despatch and should under normal conditions not go out of calibration A calibration certified sticker with the date and name of technician is located on the laser itself It is worth checking calib...

Страница 15: ...not power up A Check the rechargeable batteries are charged and connected correctly and or replace standard C size Alkaline batteries and check they are inserted correctly Q Using the receiver I get...

Страница 16: ...Charger 1 Year Warranty CMI warrants that our products will be free from defects in material and workmanship for the warranty period CMI promises to repair or replace free of charge the product or pa...