background image

2

1.  MEASURE AND MARK

 (TVMSDBWK-001 Only)

 CAUTION

Any Sensors positioned close to corners of the 
tank must be at least ½" (12.5 mm) away from the 
curvature of the tank, i.e. The centre of the probe 
must have a radius of at least at ½" (12.5 mm) of 
flat surface to mount on.

½" 

(12.5 mm)

On the side of the tank, measure out the Sensor 
positions, starting with the top Sensor at the 80% 
mark, then 60%, 40%, and 20%. Position the 
bottom Sensor as close to the bottom of the tanks 
as possible — Note that this means that the spacing 
between the Sensors may not all be equal.

Note:

 the Sensors do not have to be mounted in-line. 

The example shown ('Front' view) is acceptable.

Before drilling, check each marked location for good 
access and confirm face is flat both outside and inside 
at least 1" (25 mm) around each position.

Side

Front

80%

60%

40%

20%

Empty

2. DRILL 

(TVMSDBWK-001 Only)

Ensure tank is empty of liquid before drilling holes.

Using a sharp 

3

8

" (or 9.5 mm) drill bit, drill each marked location at 

slow speed. Ensure the cut is clean (de-burr inside and out) as any 
irregularities will prevent a good seal.

Note: 

Using a drill bit greater than 

3

8

" (or 9.5 mm) in diameter may 

prevent the Sensors from sealing properly, resulting in leaking.

3.  INSERT SENSORS 

(TVMSDBWK-001 Only)

For each Sensor, 

remove the top nut.

At each location, gently push the Sensor 

through the drilled hole until the rubber 

stopper is flush with the outer tank 

surface.

Tighten the nut to form a waterproof seal 
(the rubber is squeezed against the inner 

wall). Torque to 0.5 lbf-ft (0.7 Nm)

INSTALLATION

Содержание TVMSDBWK-001

Страница 1: ...alling this kit for a gray or black water tank refer to the TVMS1280 Instruction Manual for further information The TVMS can report five states empty one quarter one half three quarters and full The TVMS can measure the level of up to six tanks A separate TVMSDBWK 001 is required for each tank For more information refer to the RedVision Instruction Manual available on the REDARC website TVMSDBWK 0...

Страница 2: ...ach marked location for good access and confirm face is flat both outside and inside at least 1 25 mm around each position Side Front 80 60 40 20 Empty 2 DRILL TVMSDBWK 001 Only Ensure tank is empty of liquid before drilling holes Using a sharp 3 8 or 9 5 mm drill bit drill each marked location at slow speed Ensure the cut is clean de burr inside and out as any irregularities will prevent a good s...

Страница 3: ... the second nut Torque to 0 5 lbf ft 0 7 Nm while preventing the nut closest to the tank from rotating Wire colours 80 top BLUE wire 60 WHITE wire 40 GREEN wire 20 YELLOW wire Empty bottom RED wire 5 SECURE THE LOOM Secure the Wiring Loom to the TVMS mounting surface approximately 3 100 mm from the connector Suitable options include a P clip or cable tie fastened to the mounting surface This is to...

Страница 4: ...omponent Dr Smithfield NC 27577 USA Australia 61 8 8322 4848 New Zealand 64 9 222 1024 UK Europe 44 0 20 3930 8109 USA 1 704 247 5150 Canada 1 604 260 5512 Mexico 52 558 526 2898 Design and specifications are subject to change without notice Copyright 2021 REDARC Electronics Pty Ltd All rights reserved REDARC THE POWER OF REDARC and REDVISION are trademarks of Redarc Electronics Pty Ltd CONTACT US...