background image

6

2 OPERATION

2.4.1  Charging indicator (Orange) 

This indicator is used during the fi rst three stages of charging (Boost, Absorption and 
Equalise), and fl ashes at different rates to indicate the charging mode.

Boost Mode

: Orange indicator ON-single fl ash. This mode delivers the bulk charge to the 

battery by delivering maximum constant current. This stage is time limited to cater for a 
fully discharged 40Ah battery, however the time taken in this mode does greatly depend 
on the condition and state of charge of the battery.

Absorption Mode

: Orange  indicator ON-double fl ash.

This mode must be fi nished before Equalise can take place. The charger maintains 
constant charging voltage, while the current reduces. This voltage is close to the gassing 
voltage of the electrolyte.

Equalise Mode

: Orange  indicator ON – triple fl ash.

This mode brings the battery to full charge. A higher voltage is applied to induce some 
gassing, which mixes the electrolyte, bringing the cells to equal potential. In a low 
maintenance battery, most of the hydrogen and oxygen gasses will recombine and will 
not dry out the battery.
Note that this mode is not run for Gel/AGM batteries.

2.4.2  Ready indicator (Green)

Continuously ON

: Indicates that the battery charging process is complete, and full 

charge (100%) has been achieved. The charger is now in the maintenance mode (Float), 
where it will keep the battery at full charge indefi nitely without the fear of overcharging.  
The battery is ready for use, and can be disconnected.

Flashing

: Indicates that the battery charging process is complete, and full charge (100%) 

has been achieved. The charger is now in the maintenance mode (Float), where it will 
keep the battery at full charge indefi nitely without the fear of overcharging.  The battery 
is ready for use, and can be disconnected.

Содержание SBC1205

Страница 1: ...Multi stage Smart Battery Chargers SBC1205 SBC24025 ...

Страница 2: ...vehicle Do NOT use the SBC to charge non rechargeable batteries Doing so may result in harm to the user and or damage to the SBC Only use the SBC for charging Standard Lead Acid Calcium content Gel AGM type 6 cell 12V batteries All lead acid batteries produce harmful explosive gases The Battery should be mounted in a well ventilated area as far as possible from any ignition sources Do NOT smoke wh...

Страница 3: ... Operation 08 4 Other Info 09 1 Charging Time Battery Capacity 09 2 Calcium Batteries 09 5 Two Year Warranty 10 Specifications SBC1205 SBC24025 AC Input Voltage Range 216 265V AC 50Hz 216 265V AC 50Hz Input Fusing 2A Slow Blow 2A Slow Blow Output Fusing 10A 5A Nominal Output Voltage 12V 24V Output Voltage Range 12 16 5V 24 33V Output Current Range 0 5A 0 2 5A Output Power 80W 80W Weight 1 55kg 1 5...

Страница 4: ...charging the battery in the vehicle If that is not possible then find a convenient safe place where the charger is secure and not likely to fall down NOTE Never place the charger on top of the battery Leave the vent caps closed as modern automotive batteries have a gas recombination design built into the cap to allow the retention of the gassed electrolyte and its return to the battery cell All ven...

Страница 5: ...nds has expired the selection is locked in for the remainder of the charging period and the selected battery type LED will remain permanently illuminated Should an incorrect battery be selected the battery charger should be turned off for approximately 10 seconds then turned back on The correct battery selection can now be made 2 3 The Charging Process The SBC has been designed to return a dischar...

Страница 6: ...arged by a load Instead the charger will continue in float mode The full charge cycle can only be restarted by turning the charger off waiting for approximately 10 seconds then turning it back on again 2 4 Indication The Charging indicator ORANGE will indicate one of the first 3 charging stages via a number of quick flashes followed by an OFF period When the Ready indicator GREEN is ON the battery ha...

Страница 7: ...dicator ON triple flash This mode brings the battery to full charge A higher voltage is applied to induce some gassing which mixes the electrolyte bringing the cells to equal potential In a low maintenance battery most of the hydrogen and oxygen gasses will recombine and will not dry out the battery Note that this mode is not run for Gel AGM batteries 2 4 2 Ready indicator Green Continuously ON Ind...

Страница 8: ...harge a 24V battery on a 12V charger Three Flashes Faulty battery detected Charging a battery with a dead cell will result in this fault With some batteries it might take longer to detect the fault than in others depending upon the initial level of charge and also how damaged the battery is If the battery is badly damaged the fault may show up as over current Four Flashes Overheat The charger is t...

Страница 9: ... and that any gasses emitted from the battery are safely dissipated Do not extend the output cables supplied between the charger and the battery to be charged otherwise efficiency of operation will be compromised Ensure the output clamps are firmly attached to the battery poles Incorrectly connecting the Positive Red wire and Negative Black wire at the bat tery will switch off the battery charger to...

Страница 10: ...g i e for a 50Ah battery the typical maximum charging current should be less than 20 of 50Ah 10A As a safety precaution the maximum charge time has been limited to 25 hours Please refer to Ready indicator Green Flashing in section 3 1 for a description of what hap pens if the charge cycle does time out 4 2 Calcium Batteries In the Calcium battery selection mode the charger can achieve a maximum vo...

Страница 11: ...ct including without limitation choice of location 6 4 failure to ensure proper maintenance of the Product strictly in accordance with Redarc s instructions or failure to ensure proper maintenance of any associated equipment or machinery 6 5 repairs to the Product that are not strictly in accordance with Redarc s instructions 6 6 installation repairs or maintenance of the Product by or under the s...

Страница 12: ...sistance please contact Redarc Electronics 23 Brodie Road North Lonsdale SA 08 8322 4848 power redarc com au www redarc com au Copyright 2012 Redarc Electronics Pty Ltd All rights reserved www redarc com au WARSBC REV1 ...