35
3
USER GUIDE
3.8
Factory Settings
The Manager30 is shipped with a number of settings already programmed into the unit. These settings
are set to ensure that the charger will safely charge any battery and may not reflect the actual
requirements for your battery type. It is important to review these settings and adjust as required.
SETTING
FACTORY VALUE
Battery Type
GEL
Capacity
40 Ah
Charge Mode
TOURING
Temperature Scale
Celsius
Key Tone Status
ON
Contrast
50%
Brightness
90%
Backlight Timer
30 seconds
Home Screen Timer
30 seconds
Time/Date Format
12 Hour/DD/MM/YYYY
Language
English
Max Charge Current
30 Amps
Low SoC Alarm
10%
Low Voltage Alarm
10.5 Volts
Load Disconnect
Off
DC Input Trigger
Auto
NOTICE
Modification of the ‘Advanced Settings’ menu items affect the way The Manager30 unit responds to
charging situations. Modification of these settings may result in the unit not functioning at 100% of its
capacity. These settings should only be modified if absolutely necessary and when the effects of the
changes are 100% understood.
Содержание BMS1230S3-NA
Страница 1: ...Battery Management System THE MANAGER BMS1230S3 NA ...
Страница 38: ...38 5 NOTES ...