background image

5

1 PRODUCT 

FUNCTION

1.6 Display 

Panel

The BCDC1240-LV has three Battery Type Settings available.  These settings 
enable optimal charging profi les for the auxiliary battery.  The battery type 
selected is displayed via the LEDs on the front panel in the section ‘Battery Type’.  
In addition to the battery type, the status of the charger is indicated via three 
LEDs.  The ‘Charging Status’ shows when the unit is in BOOST, ABSORPTION 
or FLOAT.  In order to give more information, the applicable LED will fl ash to 
indicate the output by the unit. The longer the fl ash, the more current the charger 
is putting out.  If the LED is ON solid, then the unit is supplying a full 25A to the 
auxiliary battery.

Standby mode is entered when the unit is not charging. In this mode, the Battery 
Type LED will blink approx once per second; the charging status LEDs will be off.  
In this mode, if the battery type wire is moved then the selected battery type will 
update.

1.7 Error 

Codes

In the event of a fault with the unit, installation, either battery or solar panel, 
both the External LED and ALL the LEDs on the unit will fl ash to indicate the 
fault type.  Flashing sequences are described in the table below.

LED State

Description

1 fl ash (1 fl ash followed by 3.5 second off)

Internal Hardware Fault

2 fl ash (2 fl ash followed by 3.5 second off)

Reserved

3 fl ash (3 fl ash followed by 3.5 second off)

Unit over temp fault

4 fl ash (4 fl ash followed by 3.5 second off)

Output Battery Fault (Volts too high)

5 fl ash (5 fl ash followed by 3.5 second off)

Input under voltage (Battery)

6 fl ash (6 fl ash followed by 3.5 second off)

Input over voltage (Battery or Solar panel)

7 fl ash (7 fl ash followed by 3.5 second off)

Reverse polarity

Figure 1.6.1 - BCDC1240-LV Front Panel

RoHS

Compliant

BCDC1240

12V 40A DC/DC

3 stage

battery charger

Designed and made in Australia

BATTERY TYPE

CHARGE STATUS

AGM/gel

Standard

Calcium

Boost

Absorption

Float

Содержание BCDC1240-LV

Страница 1: ...40A In vehicle 3 Stage 12V Battery Charger BCDC1240 LV L O W V OLTAGE THRES H O L D S L O W V O LTAGE THRES H O L D S LV ...

Страница 2: ...ctric shock or fire and will void the unit warranty Do NOT use the BCDC1240 LV to charge non rechargeable batteries Doing so may result in harm to the user and or damage to the BCDC1240 LV Only use the BCDC1240 LV for charging Standard Lead Acid Calcium content Gel AGM type 12V batteries All lead acid batteries produce harmful explosive gases The Battery should be mounted in a well ventilated area...

Страница 3: ... 12 4 Frequently Asked Questions 11 5 Two Year Warranty 14 Specifications BCDC1240 LV DC Input Voltage Range 9V 32V Gel AGM Std Lead Acid Calcium Content Absorption Voltage 14 5V 14 9V 15 3V Float Voltage 13 3V 13 3V 13 3V No Load Current 100mA Standby Current 8mA Input Fuse Rating 12V 24V 50A 30A Not supplied Output Fuse Rating 50A Not supplied Output Power 600W Ambient Temperature 20 C to 80 C M...

Страница 4: ...capable of charging the auxiliary 12V battery from a Solar source Solar charging mode is selected at time of installation The unit will accept an input directly from the solar panels and act as a MPPT Solar Regulator To select the Solar charging mode the BLUE Source Select wire can either be left disconnected or connected to GROUND 1 3 Charging Algorithm When the BCDC1240 LV is turned on it will m...

Страница 5: ... 20 secs above 15 6V Turn OFF after 20 secs above 28 2V Under voltage shutdown Shutdown if Output Battery 4V 1 5 External LED Indication A flying lead output GREEN wire is provided to connect an external indicator LED which can be mounted away from the unit for example in the vehicle cabin The positive lead of the LED will be connected to the indicator output wire flying lead provided and the nega...

Страница 6: ...ff In this mode if the battery type wire is moved then the selected battery type will update 1 7 Error Codes In the event of a fault with the unit installation either battery or solar panel both the External LED and ALL the LEDs on the unit will flash to indicate the fault type Flashing sequences are described in the table below LED State Description 1 flash 1 flash followed by 3 5 second off Inte...

Страница 7: ...tery or the Solar Input Ground wire and the Auxiliary battery to be charged This point MUST be on the chassis of the vehicle on the chassis of the trailer camper caravan NOT directly wired to the main battery 2 Wire the Output Battery Positive to the Auxiliary battery positive terminal Ideally the BCDC unit should be a maximum of 1 metre in cable length from the battery positive terminal and shoul...

Страница 8: ...ection Battery type Orange Source select Blue Input positive Calcium Alternator charge Ground Standard Lead Acid Solar charge Not connected AGM or Gel Solar charge NOTE The unit will operate optimally below 55 C with good airflow At higher temperatures the unit will de rate output current IMPORTANT NOTE Battery type selection refers to a typical installation where the battery and unit are mounted ...

Страница 9: ...d be selected for example if 8AWG wires are used to connect the unit then an 8AWG butt splice should be used If the wire gauge brought up to the unit is larger than the 8AWG then it is recommended to use a butt splice that has two different size entrys each matching the respective wire size Various butt splices are available from auto electrical suppliers Crimping provides good mechanical connecti...

Страница 10: ...ttery INPUT SOLAR INPUT 9 Figure 2 2 Standard setup for a 12V Start Battery 12V Solar Array Crimp here Solder here Figure 2 1 Ensuring a good wiring connection Slip heatshrink over wire and insert wires into butt splice Keep heatshrink away from joint until after soldering is complete and has cooled Crimp both wires to the butt splice using indent type crimpers Solder the wires to the butt splice ...

Страница 11: ...t be crimped using an appropriate crimp tool INPUT To vehicle ignition SOLAR Loads 50A Fuse Battery config wire 12 Solar Panel Array Load Fuse Note Power wires must be at least 6mm and must be crimped using an appropriate crimp tool All ground points must be connected to chassis earth Auxiliary Battery INPUT Figure 2 4 Standard setup for a 12V Solar array Figure 2 3 Standard setup for a 12V Start ...

Страница 12: ...the alternator is charging properly If the problem is still evident contact a qualified Auto Electrician or Redarc Electronics Remove all loads from the auxiliary battery and charge it overnight using a multi stage charger and then recheck the battery If the battery voltage is still low replace battery Yes No Yes Yes Yes Yes Yes Yes Yes Yes No No No No No No No No Start and run engine for 30 secon...

Страница 13: ...Camper near or in the battery compartment is generally the best position It is also a good idea to mount the BCDC to a metal surface if possible to ensure optimal heat dissipation though this is not crucial Q What does the charger do if the temperature around it rises above its operating temperature A As the temperature of the BCDC rises above a certain level the current capacity of the output is ...

Страница 14: ...13 ...

Страница 15: ...uct including without limitation choice of location 6 4 failure to ensure proper maintenance of the Product strictly in accordance with Redarc s instructions or failure to ensure proper maintenance of any associated equipment or machinery 6 5 repairs to the Product that are not strictly in accordance with Redarc s instructions 6 6 installation repairs or maintenance of the Product by or under the ...

Страница 16: ...ance please contact Redarc Electronics 23 Brodie Road North Lonsdale SA 08 8322 4848 power redarc com au www redarc com au Copyright 2012 Redarc Electronics Pty Ltd All rights reserved www redarc com au WARBCDC1240 LV REV2 ...

Отзывы: