2 INSTALLATION
2.2 Charge
Profi le Selection (ORANGE Wire)
The ORANGE wire is used to select the
Maximum
output voltage. This is achieved
by connecting in the following way:
To select
Profi le A
leave the ORANGE wire disconnected. This will set the
Maximum
voltage to 14.6V.
To select
Profi le B
connect the ORANGE wire to Common Ground. This will set
the
Maximum
voltage to 15.0V.
To select
Profi le C
connect the ORANGE wire to the RED wire (Input source
positive). This will set the
Maximum
voltage to 15.1V.
To select the
Li Profi le
connect the ORANGE wire to the GREEN wire (LED
output). This will set the charger to
Lithium mode.
Check the manufacturer’s data for your battery and ensure that the
Maximum
voltage
of the profi le you select does not exceed the manufacturer’s recommended maximum
charging voltage. If the
Maximum
voltage is too high for your battery type, please select
another charging profi le.
Not
Connected
Orange Wire
Orange Wire
Orange Wire
Red Wire
Input
Source
Positive
Midi Fuse
Green Wire
Optional
LED
Orange Wire
Figure 2.2.1 - Charge Profi le Selection