Quick Start Guide
Outside US: +1 (717) 767-6511
RAM® Series
www.redlion.net
Drawing No. LP1061-A
-2-
You are now connected to the web interface. If you should
see anything other than the screen shown above, please
refer to the RAM-6021M12 User Manual, located on our
website:
www.redlion.net
.
For more information to set up Modbus features, please
refer to the RAM-6021M12 User Manual.
Hardware Status LEDs
Red Lion Controls Technical Support
If you have followed all of the instructions up to this point,
are satisfied that you are not having an authentication
problem and your unit is still not communicating, then it is
time to contact Red Lion Technical Support at:
or call
Inside US:+1 (877) 432-9908
Outside US: +1 (717) 767-6511
Installation and Hazardous Area Warnings
All power, input and output I/O wiring must be in accordance
with Class I, Division 2 wiring methods are in accordance
with the authority having jurisdiction. This equipment is
suitable for Use in Class 1, Division 2, Groups A, B, C and D
or Non-Hazardous Locations Only.
WARNING - EXPLOSION HAZARD -
DO NOT
DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN
SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-
HAZARDOUS.
WARNING -
DO NOT REMOVE OR REPLACE PORT
CONNECTIONS WHILE CIRCUIT IS LIVE UNLESS THE
AREA IS KNOWN TO BE FREE OF IGNITIBLE
CONCENTRATIONS OF FLAMMABLE SUBSTANCES. For
the required marking for the port connections, instruction
shall be included indicating that the marking shall be
displayed on a prominent place on the end-enclosure.
These devices are open-type devices that are to be installed
in a tool only accessible enclosure suitable for the
environment.
T-Code of T4A was established.
Avertissements Pour Installation et Endroits Dangereux
Tout pouvoir, le câblage d'entrée et de sortie (I/O) doivent
être conformes aux méthodes de câblage de Classe I,
Division 2 et conformément à l'autorité compétente. Cet
équipement est adapté pour une utilisation en Classe1,
Division 2, Groupes A, B, C et D ou endroits non-dangereux
seulement
AVERTISSEMENT - RISQUE D'AVERTISSEMENT -
NE
DÉBRANCHEZ PAS L'ÉQUIPEMENT PENDANT QUE LE
CIRCUIT EST DIRECT OU À MOINS QUE
L'ENVIRONNEMENT SOIT CONNU POUR ÊTRE NON-
DANGEREUX.
AVERTISSEMENT -
NE PAS RETIRER OU REMPLACER
LES CONNEXIONS DE PORT ALORS QUE LE CIRCUIT
EST VIVRE À MOINS QUE LA RÉGION EST CONNUE
POUR ÊTRE LIBRE D'IGNITIBLE LES
CONCENTRATIONS DE SUBSTANCES INFLAMMABLES.
Pour le marquage obligatoire pour les connexions de port,
l'enseignement doit être inclus en indiquant que le
marquage doit être affichée sur une place de premier plan
dans l'enceinte.
Ces appareils sont de type ouvert matériels qui doivent être
installés dans un boîtier de l'outil accessible uniquement
adapté à l'environnement.
T-Code de T4A a été établie.
LED
State
Description
Power
ON
Power is applied to the router
W
Refer to Hardware Guide for details
RS232
ON
Link established with serial device but
no data activity
FLASH
Data transmitted/received with
attached serial device
Ethernet
ON
Link established with Ethernet device