Wired Router Hardware & Installation Guide
8
Power
specifications
Power
input
to
the
router
is
protected
against
reverse
polarity
and
over
‐
voltage.
All
routers
are
equipped
with
protection
for
reversed
polarity
and
power
surges
over
33
volts.
The
routers
are
equipped
with
an
internal
3
Amp
fuse.
Electrical
Specifications
and
Pinout
1x
Digital
Output
(DOUT)
Configuration:
Open
Collector,
reference
to
ground
Absolute
Maximum
IDC:
500mADC
(Vce
=
750mVDC)
Absolute
Maximum
VDC:
30VDC
(open
circuit)
Absolute
Minimum
VDC:
‐
0.4VDC
(open
circuit)
1x
Digital
Input
(DIN)
Configuration:
un
‐
isolated
level
detection,
reference
to
ground
Active
level:
1.6VDC
to
30VDC
Inactive
level:
0VDC
to
1.3VDC
Absolute
Minimum
VDC:
‐
0.3VDC
Absolute
Maximum
VDC:
33VDC
Leakage
IDC
at
5VDC:
150uADC
1x
Analog
Input
(Shared
with
Digital
Input)
(DIN/AI1)
Configuration:
un
‐
isolated
input,
reference
to
ground
Resolution:
1024
(ADC
10
‐
bit)
VDC
per
step:
4.8875855mVDC
Full
scale
level:
5VDC
Zero
level:
0VDC
Absolute
Minimum
VDC:
‐
0.3VDC
Absolute
Maximum
VDC:
8.3VDC
Leakage
IDC
at
5VDC:
265.96uADC
TYPE