Revised 2016-07-15
Hardware Installation
Drawing No. LP0987
Mounting the NT24k Unit
2-77
N-Tron
®
Series NT24k
®
Compact Hardware Manual
5.
Connect any communications cables to the switch.
6.
Install the power and ground wires.
7.
Apply power to the power supply.
DIN-Rail Removal Instructions
Remove the switch from standard 35mm DIN-Rail as shown in the diagram above.
1.
Ensure power from the power source is off.
2.
Disconnect power and ground wires.
3.
Disconnect any communications cables from the unit.
4.
Insert a standard flat/slotted screwdriver into the slot provided on the DIN-Rail clip.
5.
Using the base of the switch as a pivot point, apply upward force on the screwdriver to release the DIN-Rail
clip.
6.
With the DIN-Rail clip latching mechanism released, continue to rotate the switch upward and away from the
panel.
7.
Once the switch has been rotated upward, remove the screwdriver.
Carefully lift the switch upward and away from the DIN-Rail and panel.