INSTALLATION

The MDMUs are available in either a panel mount or printed circuit board 

mount design. The panel mount units are provided with a mounting clip to 
securely hold the unit in the panel cutout.

Panel Mount Installation:

1. Cut panel opening to specified 

dimensions. Remove burrs 
and clean the panel opening.

2. Install MDMU through the 

panel cutout as shown in 
Figure 1.

3. Slide mounting clip over rear 

of unit until clip is against the 
back of panel. The unit has 
slots for the locking tabs to 
hold it in the panel opening.

Note: Hold the MDMU front 

bezel in place when sliding the 
mounting clip in to position

PCB Mount Installation:

1. Prepare printed circuit board hole pattern to the specifications.
2. Unit should be hand soldered using good soldering techniques and hand 

cleaned if necessary.

4. 

ANNUNCIATOR

: Flashes at a 1 Hz rate in the Timer mode when the signal 

input (CNT) is activated.

5. 

CONSTRUCTION

: High impact black plastic case (mounting clip included 

with panel mount models).

RELATIVE HUMIDITY

: Less than 85% RH (non condensing)

7. 

WEIGHT

:

Reflective Panel Mount

: 0.275 oz (7.26 g)

Reflective PCB Mount

: 0.26 oz (6.8 g)

Transmissive Panel Mount

: 0.38 oz (10.43 g)

Transmissive PCB Mount

: 0.356 (9.75 g)

MAXIMUM RATINGS

RATING

SYMBOL

VALUE

UNITS

DC Supply Voltage

V

DD

5.5

VDC

Input Voltage, all inputs

V

IN

-0.5 to (V

DD

 +0.5)

VDC

Operating Temperature

T

A

-35 to +85

°C

Storage Temperature

T

STG

-40 to +85

°C

ELECTRICAL SPECIFICATIONS - V

DD

 = 5.0 VDC = 

10% @ 25 

C unless otherwise specified.

SYMBOL

PARAMETER

MIN

TYP

MAX

UNITS

NOTES

V

DD

Supply Voltage

4.5

5.0

5.5

VDC

Voltages outside these parameters may cause display problems

I

DD

Supply Current - Transmissive

20

25

mA

V

DD

 = 5.0 VDC - 10 KHz Counting Rate.

I

DD

Supply Current - Reflective

50

100

A

V

DD

 = 5.0 VDC - 10 KHz Counting Rate.

V

IH

Valid High Voltage

3.0

VDC

V

IL

Valid Low Voltage

1.5

VDC

I

IN

Input Leakage Current

0.1

1.0

A

Fc

Count Frequency - CNT

9.9

KHz

50% Duty cycle

T

R

,

L

RST, LATCH Pulse Width

30

sec

A

CCTB

Time Base Accuracy

0.025

BEZEL

MOUNTING CLIP

EXISTING PANEL THICKNESS

0.031" to 0.125"

(0.79 to 3.18)

LOCKING

TAB

Figure 1

2

WIRING CONNECTIONS

The electrical connections are 

made via terminal pins located on 
the back of the unit. The terminal 
pins are on 0.100" center lines and 
can be mated with the RLC Model 
HWK7 cable assembly or many 
standard 0.100" center line 
connectors. When wiring the unit, 
refer to Figure 2 to identify the 
wire position with the proper 
function.

There are certain considerations 

that should be observed when 
running the signal wires. A length 
of wire can act like an antenna, 
and the closer it is to a source of 
electrical noise, the more it 
becomes susceptible to that noise.

These are a few rules that should be followed when running these wires.

1. Never run signal wires in the same conduit or raceway with A.C. power lines, 

conductors feeding motors, solenoids, SCR controls, heaters, etc.

2. Signal wires within enclosures should be routed as far away as possible from 

contactors, control relays, transformers, and other noisy components.

3. When shielded wire is used, connect the shield to the common of the MDMU 

unit, and leave the other end of the shield disconnected and insulated from 
machine ground.

4. Connect common of the MDMU to machine ground at one point only.

V

SS

 (GND)

CNT

NO CONNECTION

NO CONNECTION

NO CONNECTION

LATCH

RST

MS1

MS2

MS3

MS4

NO CONNECTION

DP2

DP1

V

DD

Figure 2