background image

INSTALLATION

The unit is equipped with a universal mounting foot for attachment to 

standard DIN style mounting rails, including G profile rail according to 

EN50035 - G32 , and top hat (T) profile rail according to EN50022 - 35 x 7.5 

and 35 x 15. The unit should be installed in a location that does not exceed the 

maximum operating temperature and provides good air circulation. Placing the 

unit near devices that generate excessive heat should be avoided.

G Rail Installation

To install the ICM5 on a "G" style DIN rail, angle the module so that the 

upper groove of the "foot" catches under the lip of the top rail. Push the 

module toward the rail until it snaps into place. To remove a module from the 

rail, push up on the bottom of the module while pulling out away from the rail.

T Rail Installation

To install the ICM5 on a "T" style rail, angle the module so that the top 

groove of the "foot" is located over the lip of the top rail. Push the module 

toward the rail until it snaps into place. To remove a module from the rail, 

insert a screwdriver into the slot on the bottom of the "foot", and pry upwards 

on the module until it releases from the rail.

TYPICAL RS-485 CONNECTIONS USING RJ-11

1

W/RJ11

PRODUCT

RED LION

4

7

10

11

5200 BAUD

57600 BAUD

PULL

 DOWN

19200 BAUD

9600 BAUD

38400 BAUD

OFF 4 WIRE/ ON 2 WIRE

OFF 4 WIRE/ ON 2 WIRE

120

 TERMIN

AT

ION

*

** *

ON

2

1

3

*

10

8

9

6

4

5

7

PULL

 UP

CABLE

RS232

ICM5

OFF DTE/ ON DCE

OFF DTE/ ON DCE

OFF DCE/ ON DT

E

OFF DCE/ ON DT

E

OFF 422/ ON 485

OFF 422/ ON 485

**

* *

7

6

4

3

NC

2

5

1

ON

RJ-11 JUMPER

CBJ11BD5

8

9

11 12

2

3

6

5

MODEL NO.

DESCRIPTION

PART NUMBER

CBJ

ICM5

6" RJ-11 Jumper Cable

RS-232/RS-485 Converter Module

CBJ11BD5

ICM50000

ORDERING INFORMATION

TYPICAL CONNECTION FOR RS-485 DEVICES

OFF DCE/ ON DT

E

OFF DCE/ ON DT

E

OFF DTE/ ON DCE

OFF DTE/ ON DCE

PULL

 DOWN

38400 BAU

D

9600 BAUD

19200 BAU

D

57600 BAU

D

115200 BAU

D

OFF 422/ ON 485

OFF 422/ ON 485

120

 TERMINA

TION

PULL

 UP

OFF 4 WIRE/ ON 2 WIR

E

OFF 4 WIRE/ ON 2 WIR

E

7

6

8

ON

7

*

*

* *

*

2

5

3

4

1

6

RXA

RXB

**

4

NC

2

3

1

9

10

ON

* *

6

7

5

2

3

5

4

TXB

SPLY

PWR

COMM

TXA

COMM

485/

422

1

+ VDC

+VDC

COMM.

TX/RX (+) TX/RX (-)

11

LEGEND

3

1 2

TX EN.

10

6 7 8 9

4 5

RS485

COMM

1

3

2

N/C

11

8

7

4

5

6

9

10

TC

COMM

N/C

RT

D

3

1

2

AC

~ ~

AC

USER INPUTS

RLY4

COMM

24

25

RLY3

RLY2

22

23

RLY1

COMM

20

21

15

13

14

OUT

-

-

OUT

+

20mA

12 +

10V

- N/C

15

14 - COMMON

- A(+)

13

12 - B(-)

PAX

NOTE: FOR CONNECTIONS TO RS485 

PORT ON PARADIGM PRODUCTS, A & 

B ARE REVERSED.

*

 - Application Dependent

*

 - Application Dependent

Содержание ICM5

Страница 1: ...m 85 mA typical Power Supply must be Class 2 or SELV rated 2 RS 232 VOLTAGES Receive Data Pin 30 VDC max Mark Condition 0 8 VDC Space Condition 2 4 VDC Transmit Data Pin Mark Condition 8 VDC typ Space Condition 8 VDC typ 3 RS 485 VOLTAGES Differential Output Voltage 5 VDC max under no load Differential Input Voltage 5 VDC max Mark Condition 0 2 VDC Space Condition 0 2 VDC RS 485 Drive Capability U...

Страница 2: ...cation Listed below are the recommended methods of connecting the shield in order of their effectiveness a Connect the shield to earth ground protective earth at one end where the unit is mounted b Connect the shield to earth ground at both ends of the cable usually when the noise source frequency is over 1 MHz 3 Never run Signal or Control cables in the same conduit or raceway with AC power lines...

Страница 3: ...ed back This allows 2 wire half duplex operation without the use of handshake lines Both switches should be in the same position Switch 3 N C No Connection Switches 4 7 OFF DCE ON DTE These switches configure the RS 232 port to act as a DCE or DTE device With all of the switches in the DCE position pin 2 of the DB 9 connector is the RS 232 receiver and pin 3 is the RS 232 transmitter DTE configure...

Страница 4: ...dule until it releases from the rail TYPICAL RS 485 CONNECTIONS USING RJ 11 1 W RJ11 PRODUCT RED LION 4 7 10 115200 BAUD 57600 BAUD PULL DOWN 19200 BAUD 9600 BAUD 38400 BAUD OFF 4 WIRE ON 2 WIRE OFF 4 WIRE ON 2 WIRE 120Ω TERMINATION ON 2 1 3 10 8 9 6 4 5 7 PULL UP CABLE RS232 ICM5 OFF DTE ON DCE OFF DTE ON DCE OFF DCE ON DTE OFF DCE ON DTE OFF 422 ON 485 OFF 422 ON 485 7 6 4 3 NC 2 5 1 ON RJ 11 JU...

Отзывы: