38 LP1109
Graphic depiction of relay action setpoint
Graphic depiction of relay action window
100
90
80
70
60
50
40
30
20
10
0 10 20 30 40 50 60 70 80 90 100
t
Off N.O.
Off N.O.
On N.O.
On N.C.
On N.C.
Off N.C.
100
90
80
70
60
50
40
30
20
10
0 10 20 30 40 50 60 70 80 90 100
t
Off N.O.
Off N.O.
On N.O.
On N.C.
On N.C.
Off N.C.
Relay units
Relay units
Setpoint = 50
Hysteresis = 10
Hysteresis = 10
Setpoint = 50
Relay action: Increasing
Relay action: Decreasing
100
90
80
70
60
50
40
30
20
10
0 10 20 30 40 50 60 70 80 90 100
t
Off
Off
Off
1
1
2
2
On
On
On
100
90
80
70
60
50
40
30
20
10
0 10 20 30 40 50 60 70 80 90 100
t
Off
Off
Off
1
1
2
2
On
On
On
Relay units
Setpoint High = 60
Hysteresis = 5
Hysteresis = 5
Setpoint Low = 40
Relay function: Window
(shown for increasing signal)
Contact: Closed inside window =
Contact: Open inside window =
Relay units
Setpoint High = 60
Hysteresis = 5
Hysteresis = 5
Setpoint Low = 40
Relay function: Window
(shown for decreasing signal)
Contact: Closed inside window =
Contact: Open inside window =
1
2
1
2
Содержание IAMS0002
Страница 2: ......
Страница 40: ...40 LP1109...