3-WAY ISOLATION OF ANALOG SIGNALS

!

UNIVERSAL CONVERSION MODULE - INPUTS AND OUTPUTS

SELECTED VIA DIP SWITCH SETTINGS

!

OVER 100 INPUT AND OUTPUT ANALOG CONVERSION

COMBINATIONS

!

CHOOSE LINEAR OR SQUARE ROOT EXTRACTION MODEL

!

ALL RANGES ARE FACTORY PRECALIBRATED. CUSTOM FIELD

CALIBRATION IS AVAILABLE FOR ALL RANGES WHILE
MAINTAINING THE FACTORY CALIBRATION FOR FUTURE USE

!

11 to 36 VDC AND 24 VAC MODULE POWER

GENERAL DESCRIPTION

The IAMA – Universal Signal Conditioning Module Series can isolate and

convert over 100 combinations of analog signal ranges. The IAMA3535
converts and transmits signals linearly proportional to the input, while the
IAMA6262 transmits the scaled square root of the input signal. This allows the
IAMA6262 to provide a signal that is linear to flow rate in applications utilizing
a differential pressure trasducer.

DIP switch range selection eliminates the need to order and stock different

modules for each input and output signal range, and allows quick and
convenient setup for over 100 standard signal conversions. By utilizing the
Field mode of calibration, the user can customize the input and output scaling
for odd applications, including reversal of the output relative to the input.

In addition to the conversion capabilities, the IAMA modules feature

optically isolated Input/Output signal circuits and transformer isolated Power to
Input, Power to Output circuits.

The modules’ overall full scale accuracy typically exceed 0.05% depending

upon range selection and scaling. The microprocessor based design provides
ease of field scaling and the onboard E

2

PROM stores scaling values for future

recall. Both models come factory precalibrated for all input and output ranges.
Factory or custom field scaling can be selected by a simple mode switch change.
The IAMA can be factory recalibrated in the field if desired.

The modules’ environmental operating temperature range is -20

°

C to +65

°

C.

DIN rail mounting saves time and panel space. The units are equipped with
universal mounting feet for attachment to standard DIN style rails, including top
hat profile rail according to EN50022 - 35x7.5 and 35 x 15 and G profile rail
according to EN50035-G32.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

ORDERING INFORMATION

SPECIFICATIONS

1. 

POWER

: 11 to 36 VDC, 3 W max. or 24 VAC, 

±

10%, 50/60 Hz, 4.8 VA

max.

2. 

INPUT/OUTPUT RANGES

: See Tables 2 and 3

3. 

ZERO/SPAN ADJUSTMENTS

: Digital (DIP Switch Transition)

4. 

MAX INPUT SIGNAL

:

Current Input

: 110 mA DC, 1.1 VDC

Voltage Inputs

: Terminal 7-   1 VDC +10%

Terminal 8-   10 VDC +10%
Terminal 9-   100 VDC +10%

5. 

INPUT RESISTANCE

:

Current

: 10 

Voltage

: > 100 K

6. 

INPUT PROTECTION

: Surge suppressor diodes

7. 

MAX OUTPUT CURRENT

:

Current Output

: 22 mA

Voltage Output

: 10 mA

8. 

LOAD RESISTANCE

:

Current Output

600 

Voltage Output

1 K

9. 

OUTPUT COMPLIANCE

:

Current

: 4 to 20 mA, 0 to 20 mA: 12 V min (

600 

)

0 to 1 mA: 10 V min (

10 K

)

Voltage

: 10 VDC across a min. 1 K

load (10 mA). Factory calibrated for

loads of > 1 M

.

10. 

ISOLATION LEVEL INPUT TO OUTPUT

: 1.5 kV @ 50/60 Hz, 1 min

11. 

STEP RESPONSE

: To within 99% of full scale: 300 msec

MODEL IAMA - UNIVERSAL SIGNAL CONDITIONING MODULE

DIMENSIONS  In inches (mm)

CAUTION: Read complete

instructions prior to installation

and operation of the unit.

CAUTION: Risk of electric shock.

MODEL NO.

DESCRIPTION

PART NUMBER

IAMA

Square Root Universal Signal Conditioning Module

Linear Universal Signal Conditioning Module

IAMA6262

IAMA3535

Bulletin No.  IAMA-D
Drawing No.  LP0413
Released  10/02

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion-controls.com

UL Recognized Component,
File # E179259

Содержание IAMA Series

Страница 1: ...the field if desired The modules environmental operating temperature range is 20 C to 65 C DIN rail mounting saves time and panel space The units are equipped with universal mounting feet for attachment to standard DIN style rails including top hat profile rail according to EN50022 35x7 5 and 35 x 15 and G profile rail according to EN50035 G32 SAFETY SUMMARY All safety related regulations local co...

Страница 2: ...which restores the respective setting The Factory and Field E2PROM locations contain the same calibration values when the IAMA is received from the factory Therefore until the IAMA is field scaled factory and field modes perform identically See SCALING PROCEDURE for detailed instructions on field programming the IAMA The units can be scaled to any minimum scale and full scale values within the ext...

Страница 3: ...ive earth b Connect the shield to earth ground at both ends of the cable usually when the noise source frequency is above 1 MHz c Connect the shield to common of the unit and leave the other end of the shield unconnected and insulated from earth ground 2 Never run Signal or Control cables in the same conduit or raceway with AC power lines conductors feeding motors solenoids SCR controls and heater...

Страница 4: ...t 100 VDC Terminal 10 max signal input 100 mA Terminal 12 signal common 1 3 Set Input Range switches S1 switches 6 through 10 to the desired Input Range See Table 3 0 to 10 VDC range shown 1 4 Set Input Field Fact switch S1 switch 2 to the off position 1 5 Apply power to the IAMA Solid illumination of Green LED if signal is within the minimum and maximum limits of the selected input range Slow bli...

Страница 5: ...the Red LED blinks slowly and the Green LED turns off Removing power aborts scaling begin at Step 2 1 2 9 Apply maximum scale input The Red and Green LEDs will alternately blink 2 10 Set Input Field Fact switch S1 switch 2 to the on position Red LED extinguishes and Green LED becomes solid Your scaled values are now saved and recalled if the Input Field Fact switch S1 switch 2 is in the on positio...

Страница 6: ...max signal input 10 VDC Terminal 9 max signal input 100 VDC Terminal 10 max signal input 100 mA Terminal 12 signal common 4 9 Apply power to the IAMA and allow a warm up period of five minutes 4 10 Set Output Field Fact switch S1 switch 1 to the on position The Red and Green LEDs will alternately blink If Red LED blinks slowly increase signal until Red and Green LEDs alternately blink 4 11 Adjust ...

Страница 7: ... calibration is to be completed return S1 1 and S1 2 to the down position and remove power from the IAMA Apply power and check for accurate operation of the newly calibrated range or ranges OUTPUT RECALIBRATION 1 Complete 1 through 5 of the input recalibration procedure for at least one range 2 For current output set 20 mA 1 mA switch S2 to desired full scale output 20 mA on 1 mA off 3 Set Output ...

Страница 8: ...elies on no other warranties or affirmations APPLICATION Cost efficiency measurements of a printing company included the reduction of bulk stock of the various inks used in their printing processes The company currently had various ink flow and level devices with different current and voltage outputs and wanted to record these measurements into a control room PC Several IAMA Universal Signal Condi...

Отзывы: