background image

 

 

www.redlion.net 

 
 
 

 

 
 

 

 

EL212F 

Industrial Ethernet 

Managed Switch 

 
 

Installation Guide 

 
 
 
 
 
 
 
 
 

Revision: 16 January 2014 

 

Содержание EL212F

Страница 1: ...www redlion net EL212F Industrial Ethernet Managed Switch Installation Guide Revision 16 January 2014 ...

Страница 2: ...EL212 Installation Guide Rev 16 Jan 14 Page 2 of 28 This page intentionally left blank ...

Страница 3: ...nstallation Guide Rev 16 Jan 14 Page 3 of 28 Management Guide Installation Guide Industrial Ethernet Switch Layer 2 with 8 4G 8 100BASE BX SFP Ports 2 1000BASE T SFP Ports 2 Combination Gigabit RJ45 SFP Ports ...

Страница 4: ...n to related features or instructions Caution risk of danger Alerts you to a potential hazard that could cause loss of data or damage the system or equipment Documentation must be consulted in all cases where this symbol is marked Typical caution symbol Warning risk of electrical shock Alerts you to a potential hazard that could cause personal injury Typical warning symbol Related Publications The...

Страница 5: ...tenance and removal of the switch must be carried out by qualified personnel only Warning Install the Managed Switches in accordance with local and national electrical codes Warning The unit must be properly grounded to comply with international standards Warning If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Warning Do n...

Страница 6: ...Commutateurs Gérés conformément aux codes électriques locaux et nationaux Avertissement L appareil doit être correctement mis à la terre afin de se conformer aux normes internationales Avertissement Si l équipement est utilisé d une manière non spécifiée par le fabricant la protection fournie par l équipement peut être altérée Avertissement Ne pas se connecter à une source d alimentation CA sans u...

Страница 7: ...ber fiber plugs inserted when the fiber port is not being used Hi Pot Dielectric Testing Caution This device is designed to withstand a high potential hi pot dielectric test up to 2000 VAC or 2800 VDC 1 minute or 2400 VAC or 3300 VDC 1 second according to IEEE 1613 However the surge circuitry must be bypassed before performing this test See section 8 for details Power Markings Direct Current DC Al...

Страница 8: ...ment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Notice Shiel...

Страница 9: ...ny particular purpose All such warranties are hereby expressly disclaimed No oral or written information or advice given by Red Lion or Red Lion s representative shall create a warranty or in any way increase the scope of this warranty This limited warranty is in lieu of all other warranties whether oral or written expressed or implied Red Lion s liability shall not exceed the price of the individ...

Страница 10: ...ion 2 Installation and Mounting Page 13 Section 3 Thermal Considerations Page 15 Section 4 Power and Output Wiring Page 16 Section 5 Communication Wiring Page 19 Section 6 LED Indicators Page 23 Section 7 Reset Button Page 24 Section 8 Technical Specifications Page 25 Section 9 Service Information Page 27 ...

Страница 11: ...andwidth and speed reduction or elimination of message collisions and deterministic performance when tied with real time systems These industrial Ethernet switches support 10BaseT 10 Mbps 100BaseT 100 Mbps and 100BaseF 100 Mbps fiber connections on the first 18 ports This is accomplished by way of pluggable SFP transceivers The 4 Gigabit ports supports 10 100 1000BaseT 10 100 1000 Mbps on their RJ...

Страница 12: ...r cUL Zone 2 ATEX Only EL212F DC V1 is approved for Zone 2 ATEX areas EMC emissions and immunity CE per the EMC directive IEC 61000 6 2 Immunity in industrial environments IEC 61000 6 4 Emissions in industrial environments FCC part 15 and ICES 003 See FCC statement on page 7 EN 55022 CISPR22 IEC 61850 EMC immunity mechanical and climatic conditions in power substations IEC TS 61000 6 5 EMC immunit...

Страница 13: ... allow enough room to route your Ethernet copper or fiber optic cables Also please consult the specifications for your fiber optic cable to make sure you allow for the proper bend radius Important Note Make sure to read Section 3 regarding thermal considerations before installing your switch Note AutoCAD and other drawings are available on the CD or at www redlion net ...

Страница 14: ...EL212 Installation Guide Rev 16 Jan 14 Page 14 of 28 Mechanical Dimensions for the EL212 ...

Страница 15: ...h to conduct the heat from the components to the heavy gauge aluminum case The heat is then dissipated from the case via radiation to the surrounding air Note An air gap is not absolutely necessary but highly recommended when you know that the switch will experience high heat 60 C for extended periods of time BTU Hour The power consumption of the switch can be as much as 45 Watts with all ports li...

Страница 16: ... your input power is within the ranges as defined above Otherwise you may damage your switch by applying the wrong power Safety Grounding For the highest electrical safety the EL212F switches are provided with several grounding points First there are two green ground screws see images that attach directly to the switch case They are supplied pre installed on one side of the switch but they can be ...

Страница 17: ...e and the ground is green or green yellow Positive DC Power Systems For positive power systems such as 24 VDC put the positive lead on the terminal marked L and the return or ground lead on the terminal marked N If there is a chassis earth or safety ground lead then put it on the associated terminal marked with the chassis ground symbol Negative DC Power Systems Both the power option A and D suppo...

Страница 18: ...mum current 2 A 30 VDC or 250 VAC Minimum load 10 mVDC 10 µA The relay will operate as follows Condition NO Contact NC Contact No power to switch Closed shorted to common Open Switch powered with no alarms Open Closed shorted to common Switch powered with an alarm Closed shorted to common Open Alarm Wiring for EL212 Switches NC C NO Pluggable Screw Block 1 2 3 4 5 6 7 8 9 10 Accepts 14 24 AWG Wire...

Страница 19: ...device the switch is to be connected to as all the ports are capable of auto mdi mdix crossover detection The RJ45 Ethernet port connector bodies on these products are metallic and are connected to the Chassis GND terminal Therefore shielded cables should be used to provide further protection from electrical noise and interference Ideally to prevent ground loops the cable shield should be tied to ...

Страница 20: ...port 10 100 Mbps RJ45 copper or 100 Mbps fiber optic SFP transceivers On these 8 ports you can mix and match copper and fiber as desired Typical SFP Transceivers The SFP transceivers just plug into the SFP cages To lock them in place lift the locking arm as shown in the image above To remove a transceiver first pull down on the locking release arm and then pull the transceiver out The transceivers...

Страница 21: ...nnectivity After all Ethernet and or fiber connections are made check the LED s corresponding to the ports that each of the devices are connected to Ensure that for each port that is in use the LED is on or blinking If a port LED is off go back and check for connectivity problems between that port and the network device connected to that particular port Console Port Management The switch can be so...

Страница 22: ...is available from any computer store If your PC does not have a serial DB9 port then you can purchase an inexpensive USB to Serial converter from any computer store or use the USB port on the switch Switch DB9 Female Typical Null modem Cable DB9F to DB9F PC DB9 Female DB9M Pin Signal Name Signal Name DB9M Pin 1 CD in CD in 1 2 RD in RD in 2 3 TD out TD out 3 4 DTR out DTR out 4 5 GND GND 5 6 DSR i...

Страница 23: ...Indicates that there is not a proper Ethernet connection Link Make sure the cable has been properly connected at both ends Status LED The Status LED indicates the overall health of the switch It is normally ON solid indicating that no internal CPU or software problems are detected It will flash on power up or reset Otherwise if it is OFF or flashing for an extended period of time then a problem is...

Страница 24: ... the front of the switch near the status LED See the image below Simply use a straightened paper clip to push in the reset button There is one mode of operation as described below Hardware Reset To simply perform a hardware reset just push in the reset button momentarily The switch will then immediately perform a hardware reset which takes around 2 minutes The switch will not function or be access...

Страница 25: ...Registration MVR IEEE 802 1ab Link layer Discovery Protocol LLDP Quality of Service QoS with 4 priority queues o Scheduling schemes WRR and Strict priority o CoS per IEEE 802 1p and IP DSCP based o DiffServ DS ingress egress and remarking Rate limiting ingress and egress o 64Kbps to 100 1000Mbps o Per port CoS SECURITY Enable disable ports Port security MAC based static and dynamic DHCP Snooping a...

Страница 26: ...nt metal enclosure Dimensions HxWxD 1 75 1U x17 3x12 45x439x305mm Weight typical 5 5 lbs 2 5 kg ENVIRONMENTAL Operating storage temperature Designed and tested to 40 to 85 C per IEC 60068 2 1 2 Humidity 5 to 95 RH non condensing per IEC 60068 2 78 Vibration 20mm s from 1 to 150 Hz per IEEE 1613 Class V S 3 Vibration Amp 3mm from 2 9 Hz 1g from 9 200Hz 1 5g from 200 500 Hz per IEC 61850 3 Shock 30g...

Страница 27: ...ase supply us with as many details about the problem as you can The information you supply will be written on the RO form and supplied to the repair department before your unit arrives This helps us to provide you with the best service in the fastest manner Repairs are completed as soon as possible If you need a quicker turnaround ship the unit to us by air freight We give priority service to equi...

Страница 28: ...EL212 Installation Guide Rev 16 Jan 14 Page 28 of 28 This page intentionally left blank ...