WIRING CONNECTIONS

The electrical connections are made via rear screw-clamp terminals located 

on the back of the unit. When wiring the unit, use the label to identify the wire 
position with the proper function. All conductors should meet voltage and 
current ratings for each terminal. Also cabling should conform to appropriate 
standards of good installation, local codes and regulations. It is recommended 
that power supplied to the unit (AC or DC) be protected by a fuse or circuit 
breaker. Strip the wire, leaving approximately 1/4" bare wire exposed 

(stranded 

wires should be tinned with solder)

. Insert the wire into the screw-clamp 

terminal and tighten down the screw until the wire is clamped tightly. Each 
terminal can accept up to two #14 AWG wires. 

Note: The Reflective CUB4 will NOT have a screw terminal installed at the V+ 

terminal, since it is NOT required for operation and is not internally 
connected. Refer to the Ordering Information for the part number of a 
reflective model that will accommodate the MLPS.

Backlight Wiring

Optional backlight versions of the CUB4 require an external 9-28 VDC 

power supply. The external supply is connected between the V+ and Common 
terminals.

Warning:

 

Lithium battery may explode if incinerated.

Caution: All leads will be at the same line potential as the input leads.

9-28 VDC            2  

10-300V

1 COM.

YORK, PA. 

RED LION CONTROLS

EXPLODE IF INCINERATED

LITHIUM BATTERY MAY

WARNING

!

MADE IN U.S.A.

 CUB4L8W

4 REM. RST.

3 RST.

EN.

M2061C

L.S.  5

L.S. INPUT, 30 CPS MAX.

The CUB4L8W accepts most machine control voltage signals. The input 

accepts AC (50/60 Hz) or DC control voltages from 10 to 300 V at count 
speeds up to 30 cps. The unit counts on the positive going edge of the input 
signal.

WARNING

: Any lead may be at hazardous live input potential. 

External wiring and devices connected to the unit must be rated 
the same as applied signal input voltage and be properly 
isolated from Class 2 or SELV circuitry.

+3V

MICRO

CHIP

COMM.

940K

BATT.
3.0V

L.S. 

COMMON

TROUBLESHOOTING

For further technical assistance, contact technical support at the appropriate company numbers listed. 

RESET OPTIONS

Connecting a wire from the 

“RST. EN.” (Reset Enable)

 Input terminal to 

Common will enable the front panel Reset button. When Remote Reset is 
required, a wire is connected from the “

REM. RST.”

 input terminal to 

Common. Pulling this input low causes the counter to reset. The 

“REM. RST.”

 

can be pulled low by either a mechanical switch or solid-state transistor 
switch.  Switch load and leakage are the same as for “

L.S. CNT.”

 Input above.

Note: The RC protection circuit on the “REM. RST.” Input causes a delay of 

approximately 15 msec in Reset response.

BACKLIGHT OPTION

Optional backlight versions of the CUB4 require an external 9-28 VDC 

power supply. The external supply is connected between the V+ and Common 
terminals as shown in the drawing.

Red Lion Controls optional power supply (MLPS1000) is designed to be 

attached directly to the rear of a CUB4 and is powered from a 85 to 250 VAC 
source. The MLPS provides power for unit backlighting and a sensor.

WARNING

: When connecting the wiring for a backlit CUB4L8W 

measuring an AC input voltage, the neutral of the single phase AC 
signal is connected to Terminal 1 (COM), and line (hot) is 
connected to Terminal 5 (LS). The DC supply for the backlighting 
is connected as shown in the drawing. Three phase AC applications 
require an isolation transformer.

+3V

MICRO

CHIP

COMM.

220K

220K

BATT.
3.0V

REM. RST.

COMMON

RST. EN.

FRONT
PANEL

RESET

REMOTE

RESET

TO COUNT

SIGNAL

COMMON

9-26 VDC

POWER SUPPLY

or MLPS

(Backlighting) 

NEUTRAL

SIGNAL
LINE (HOT)

+

-

1 COM.

YORK, PA. 

RED LION CONTROLS

EXPLODE IF INCINERATED

LITHIUM BATTERY MAY

WARNING

!

MADE IN U.S.A.

 CUB4L8W

4 REM. RST.

3 RST.

EN.

M2061C

10-300V

L.S.  5

9-28 VDC            2  

Содержание CUB4L8W

Страница 1: ...tection provided by the equipment may be impaired SPECIFICATIONS 1 DISPLAY 8 Digit LCD 0 46 11 7 mm high digits 2 POWER SOURCE Internal 3 0 V lithium battery to provide up to 6 years of continuous operation Battery life is dependent upon usage Count and reset contacts that remain closed for long periods of time will reduce battery life 3 BACKLIGHT POWER REQUIREMENTS 9 to 28 VDC 35 mA typical 50 mA...

Страница 2: ...mponents 4 In extremely high EMI environments the use of external EMI suppression devices such as ferrite suppression cores is effective Install them on Signal and Control cables as close to the unit as possible Loop the cable through the core several times or use multiple cores on each cable for additional protection Install line filters on the power input cable to the unit to suppress power line...

Страница 3: ...otential External wiring and devices connected to the unit must be rated the same as applied signal input voltage and be properly isolated from Class 2 or SELV circuitry 3V MICRO CHIP COMM 940K BATT 3 0V L S COMMON TROUBLESHOOTING For further technical assistance contact technical support at the appropriate company numbers listed RESET OPTIONS Connecting a wire from the RST EN Reset Enable Input t...

Страница 4: ...r replacement of a defective product at The Company s option The Company disclaims all liability for any affirmation promise or representation with respect to the products The customer agrees to hold Red Lion Controls harmless from defend and indemnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and b...

Отзывы: