20 Willow Springs Circle
• York, PA 17406 • USA • T +1 717 767 6511 • [email protected]
QUICK START GUIDE
ATM Cellular Routers
Models A-2200 and A-2201
Rev 6
– November 12, 2009
HYOSUNG IP ATM SETUP
Host Processor
Data Stream
(ASAI)
RBS World Pay
Metavante
Network Type
TCP/IP
TCP/IP
TCP/IP
TCP/IP Type Defined
Standard
Standard
Standard
CRC Check Mode (CRC
Option)
Enable
Disable
Disable
EOT Customer Defined
EOT Required
EOT Required
EOT Required
SSL Option
Disable
Disable
Disable
Host IP Address
192.168.1.1
192.168.1.1
192.168.1.1
Host IP Port
7004
449
450
ATM IP Address
192.168.1.2
192.168.1.2
192.168.1.2
Subnet Mask
255.255.255.0
255.255.255.0
255.255.255.0
Default Router
192.168.1.1
192.168.1.1
192.168.1.1
Note: The ATM’s Ethernet settings can be to be set to DHCP (Obtain IP Automatically).
Once the A2200/A2201 has been powered on you must wait for the
signal strength meter to go solid before attempting a transaction. If you
are using an A2201 for a dial ATM be sure the ON LED (the Green LED
by the Dial Port) is lit as well.
The A2200/A2201 provides a signal strength meter (Light Bar) that can
be used to assist in placing the external antenna in the optimum location
to enhance the signal strength. The Light Bar provides a visual indication
of the RSSI Signal Strength.
The Light Bar updates every 2 seconds. Therefore when moving the
antenna around to find optimum signal strength be sure to leave it in
place for at least 5 seconds before checking the signal again.
The Light Bar pulses once every two seconds until it establishes a PPP
connection to the Tower. Once the Light Bar goes from pulsing every two
seconds to being solidly lit the A2200/A2201 is connected to the Internet.
Lights
Signal Strength
Four LEDs
Excellent
Three LEDs
Good
Two LEDs
Poor
Top and Bottom LEDs flashing
No Signal
Top and Bottom Leds solid
Connected to the Network at a
very low signal. The connection is
unreliable and is highly
recommended that other options
are considered to improve signal.
1
–4 LEDs strobing (on solid, flash,
on solid, flash in a continuing
sequence once
every two seconds)
No PPP Connection. This is
displayed when the connection to
the cell tower is available but the
connection through the cell
network to the destination server is
not established.
Four LEDs flashing rapidly
Low cell modem memory detected
Your ATM is now ready to process a transaction please complete a
balance enquiry to test the machine.
TROUBLESHOOTING
Move the antenna.
Install a better antenna.
Extension Cable to reposition the antenna.
Install an In Line Powered Amplifier.
Before calling Technical Support, please fully program and test your
ATM on a land line ensuring your ATM is functional. If you have followed
these steps and your ATM is not working properly, please contact us at
1
877 432 9908.
Technical Support hours are Monday-Friday from 8:45 am
to 5:30pm EST.
TERMS MAY APPEAR IN THIS MANUAL
WARNING. Warning statements identify conditions
or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or
practices that could result in damage to this product
or to other property.
These terms may appear on the product:
DANGER indicates an injury hazard immediately
accessible as you read the marking.
WARNING
indicates
an
injury
hazard
not
immediately accessible as you read the marking.
Caution
indicates a hazard to property including the
product.
SAFETY RULES
Please read the following safety information carefully before installing the
Router
WARNING
Cover to be removed by qualified
personnel.
Disconnect power before servicing.
The unit must be connected to an earthed (grounded) outlet to
comply with international safety standards.
Do not connect the unit to an A.C. outlet (power supply) without
an earth (grounded) connection.
If the Router is provided with an IEC320 plug, the appliance
coupler (the connector to the unit and not the wall plug) must
have a configuration for mating with an EN60320/IEC320
appliance inlet.
The socket outlet must be near to the unit and easily accessible.
You can only remove power from the unit by disconnecting the
power cord from the outlet.
This unit operates under SELV (Safety Extra Low Voltage)
conditions according to IEC 60. The conditions are only
maintained if the equipment to which it is connected also
operates under SELV conditions.
OPERATING ENVIRONMENT
The following environmental conditions are required:
Operating temp: 32° to 104° F maximum (0° to 40° C
maximum)
Storage temp: -40° to +158° F maximum (-40° to +70° C
maximum)
Relative humidity: 5% to 95% (non-condensing)
Terms in This
Manual
Terms on the
Product
DANGER
High
Voltage