1.
DISPLAY
: 8 digit LCD 0.46" (11.7 mm) high digits
CUB5R000
: Reflective LCD with full viewing angle
CUB5B000
: Transmissive LCD with selectable red or green LED backlight,
viewing angle optimized. Display color change capability with output state
when using an output module.
2.
POWER
: Input voltage range is +9 to +28 VDC with short circuit and input
polarity protection. Must use an RLC model MLPS1 or a Class 2 or SELV
rated power supply.
3.
COUNTER DISPLAYS
:
Counter A
: 8-digits, enabled in all count modes
Display Range: -9999999 to 99999999
Overflow Indication: Display flashes “
Cnt OVEr
”
Counter B
: 7-digits, enabled in Dual Counter Mode or batch counting
Display Designator: “
b
” to the left side of the display
Display Range: 0 to 9999999 (positive count only)
Overflow Indication: Display flashes “
bCntOVEr
”
Maximum Count Rates
: 50% duty cycle
Without setpoint option card: 20 KHz (all count modes)
With setpoint option card: 20 KHz for any count mode except Dual Counter
(16 KHz), Quadrature x2 (14 KHz) and Quadrature x4 (13 KHz).
4.
RATE DISPLAY
: 6-digits, may be enabled or disabled in any count mode
Display Designator
: “
R
” to the left side of the display
Display Range
: 0 to 999999
Over Range Display
: “
R OLOLOL
”
Maximum Frequency
: 20 KHz
Minimum Frequency
: 0.01 Hz
Accuracy
: ±0.01%
5.
COUNT/RATE SIGNAL INPUTS (INP A and INP B):
Input A
: DIP switch selectable to accept pulses from a variety of sources.
See Section 2.0 Setting the DIP Switches for Input A specifications.
Input B
: Logic signals only
Trigger levels: V
IL
= 1.0 V max; V
IH
= 2.4 V min; V
MAX
= 28 VDC
Current sinking: Internal 10K
Ω
pull-up resistor to +9 to 28 VDC
Filter (LO Freq.): Damping capacitor provided for switch contact bounce.
Limits input frequency to 50 Hz and input pulse widths to 10 msec min.
6.
USER INPUT (USR):
Programmable input. Connect to input common (INP
COMM) to activate function. Internal 10K
Ω
pull-up resistor to +9 to 28 VDC.
Threshold Levels
: V
IL
= 1.0 V max; V
IH
= 2.4 V min; V
MAX
= 28 VDC
Response Time
: 5 msec typ.; 50 msec debounce (activation and release)
7.
MEMORY
: Nonvolatile E
2
PROM memory retains all programming
parameters and count values when power is removed.
8.
CONNECTIONS
: Wire clamping screw terminals
Wire Strip Length
: 0.3" (7.5 mm)
Wire Gage
: 30-14 AWG copper wire
Torque
: 5 inch-lbs (0.565 N-m) max.
9.
CONSTRUCTION
: This unit is rated for NEMA 4X/IP65 requirements for
indoor use. Installation Category I, Pollution Degree 2. High impact plastic
case with clear viewing window. Panel gasket and mounting clip included.
10
.
ENVIRONMENTAL CONDITIONS
:
Operating Temperature Range for CUB5R000
: -35 to 75°C
Operating Temperature Range for CUB5B000 depends on display color
and intensity level as per below
:
Storage Temperature
: -35 to 85°C
Operating and Storage Humidity
: 0 to 85% max. relative humidity (non-
condensing)
Vibration According to IEC 68-2-6
: 5 to 500 Hz, in X, Y, Z direction for 1.5
hours, 5 g’s.
Shock According to IEC 68-2-27
: Operational 40 g, 11 msec in 3 directions.
Altitude
: Up to 2000 meters
11.
CERTIFICATIONS AND COMPLIANCES
:
SAFETY
UL Recognized Component, File #E179259, UL61010A-1, CSA 22.2 No. 61010-1
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Type 4X Indoor Enclosure rating (Face only), UL50
IECEE CB Scheme Test Certificate #US/9257C/UL
CB Scheme Test Report #E179259-V01-S02
Issued by Underwriters Laboratories, Inc.
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for
Measurement, Control and Laboratory use.
Notes:
1. Criterion A: Normal operation within specified limits.
Refer to EMC Installation Guidelines for additional information.
12.
WEIGHT
: 3.2 oz (100 g)
2
G
ENERAL
M
ETER
S
PECIFICATIONS
O
RDERING
I
NFORMATION
TYPE
MODEL NO.
DESCRIPTION
PART NUMBER
CUB5
CUB5R
CUB5R000
CUB5B
CUB5B000
Optional Plug-in Cards
CUB5SNK
CUB5RLY
CUB5COM
RS232 Serial Communications Card
RS485 Serial Communications Card
Dual Sinking Open Collector Output card
Single Relay Option Card
CUB5COM2
CUB5COM1
CUB5SNK0
CUB5RLY0
Accessories
SFCRD
CBLPRO
CBPRO
MLPS1
Crimson 2 PC Configuration Software for Windows 98, ME, 2000, XP
*
Programming Cable RS232 (RJ11-DB9)
Programming Cable RS485 (RJ11-DB9)
Micro-Line Power Supply, 85 to 250 VAC
SFCRD200
CBLPROG0
CBPRO007
MLPS1000
Dual Counter & Rate Indicator with Reflective Display
Dual Counter & Rate Indicator with Backlight Display
MODEL
NO.
DISPLAY COLOR
INPUT CURRENT
@ 9 VDC WITHOUT
CUB5RLY0
CUB5R000
---
10 mA
30 mA
CUB5B000
Red (max intensity)
85 mA
115 mA
CUB5B000
Green (max intensity)
95 mA
125 mA
TEMPERATURE
1 & 2
-35 to 75°C
3
-35 to 70°C
4
-35 to 60°C
5
-35 to 50°C
1 & 2
-35 to 75°C
3
-35 to 65°C
5
4
-35 to 35°C
-35 to 50°C
INTENSITY LEVEL
Class A
EN 55011
Emissions
Emissions:
30 A/m
3 V/rms
Criterion A
Criterion A
EN 61000-4-8
EN 61000-4-6
RF conducted interference
1 kV L-L,
Criterion A
EN 61000-4-5
Surge
1 kV signal
2 kV power
Criterion A
EN 61000-4-4
Fast transients (burst)
2 kV L&N-E power
10 V/m
Criterion A
EN 61000-4-3
Electromagnetic RF fields
8 kV air discharge
4 kV contact discharge
Criterion A
EN 61000-4-2
Electrostatic discharge
Immunity to Industrial Locations:
Power frequency magnetic fields
Green Display
*Crimson 2 software is available for download from http://www.redlion.net/
Red Display
INPUT CURRENT
@ 9 VDC WITH
CUB5RLY0