15
16-SETTINGS MENU
Technical Dept. - All rights reserved - Reproduction prohibited
AUTOECO (factory activated)
The Auto eco mode turns the boiler off when heating the system does not require heat, depending on the menu-settings-input aux
configuration.
AUTO ECO ACTIVE
The AutoEco active parameter (factory settings) is shown on the top right on the control panel display in the main screen. If heat is not
required, the boiler turns off after the set time, switching to Auto Eco (State 84 - it is possible to see Auto eco in the Information Menu,
boiler state).
NOTE: With the boiler off, if T is set less than T room, or other heat request settings are fulfilled, the boiler does not turn on.
1 = no heat request (T room > T set)
heat request:
heating
sanitary
puffer
AUTO ECO DEACTIVATED
With the boiler on, if Auto eco is deactivated and there are no heat requests (different based on menu-settings-aux input settings) the
boiler operates at minimum power.
The required condition for restarting is for there to be heat request for at least consecutive 10’’; it is possible to restart if:
• at least 5 s have elapsed from when shutdown began
• the TH
2
O in the boiler is < T set H
2
O
To modify the function
:
from the Settings menu - using the arrow keys, select the AUTOECO function, press ok (E key) and press D or C key (arrow key) and select:
Activate = to modify the set time from 0 to 30 minutes (factory default 5 minutes)
Deactivate = to deactivate Auto Eco
B
E
INFO
OK
C
D
ACTIVATE
AUTOECO
DEACTIVATE
AUTOECO
B
EXIT
IF YOU ACTIVATE THE AUTOECO,
THE STOVE GOES OFF WHEN THERE
ARE NO MORE HEAT REQUESTS
SETTINGS-AUTOECO
1
MENU
B
E
25° ECO
ON
ECO
TIMER1
10:13
TEMP
63°
23°
D