9.  STORAGE INSTRUCTIONS

1.  Charge battery to full capacity before storage.

2.  Store this unit at temperatures between -5°F-+140°F (-20°C-+60°C).

3.  Never completely discharge the battery.

4.  Charge after each use.

5.  Charge at least once every month, if not in frequent use, to prevent  

over-discharge.

10.  TROUBLESHOOTING

Jump Starter

PROBLEM

SOLUTION

The jump starter’s display will 

not turn on.

Make sure the unit is charged.

Connect to a power source, to reset.

Make sure the ON/OFF switch is set to 

the ON position.

 

The thermometer symbol  

is flashing.

The unit is too hot or cold. The thermometer 

symbol will disappear when the condition 

is removed.

The jump starter will not 

recharge.

Make sure the power source is live.

The jump starter turns on, but 

won’t jump start my vehicle.

Check connections.

Verify the charge level of the jump starter is 

at least 40%. 

Do not attempt to jump start your vehicle 

more than three consecutive times. If 

the vehicle still does not start, consult a 

qualified service technician.

When cable is connected only 

to the battery: Solid Red LED, 

(Green LED off); beeps once 

per second

The vehical battery voltage is lower than 

10.5V. User can connect to jump starter 

and turn key to jump start the vehicle.

When cable is correctly 

connected to both battery 

and jump starter: Green LED 

blinking; Red LED off; no beep.

“Fake” high battery voltage is detected, 

but reverse charging protection did not 

activate. User can turn key to jump start 

the vehicle.

Smart Cable LED and Alarm Behavior

BEHAVIOR

REASON

Green LED blinking; Red LED 

off; no beep.

Cable is connected to battery only.

Cable is connected to jump starter only.

Green LED solid; Red LED off; 

no beep. 

Cable is connected correctly to both 

battery and jump starter.

Содержание SL161

Страница 1: ...ill explain how to use the unit safely and effectively Please read and follow these instructions and precautions carefully POR FAVOR GUARDE ESTE MANUAL DEL PROPIETARIO Y LEER ANTES DE CADA USO En este manual se explica cómo utilizar la unidad segura y efectiva Por favor lea y siga las siguientes instrucciones y precauciones ...

Страница 2: ...the SL161 may result in a risk of fire electric shock or injury to persons or damage to property 1 6 To reduce the risk of damage to the electric plug or cord pull by the adaptor rather than the cord when disconnecting the unit 1 7 Do not operate the unit with damaged cables or clamps 1 8 Do not operate the unit if it has received a sharp blow been dropped or otherwise damaged in any way take it t...

Страница 3: ...ing 2 8 Wear complete eye and body protection including safety goggles and protective clothing Avoid touching your eyes while working near the battery 2 9 If battery acid contacts your skin or clothing immediately wash the area with soap and water If acid enters your eye immediately flood the eye with cold running water for at least 10 minutes and get medical attention right away 2 10 If battery a...

Страница 4: ...tal part of the battery clips or cut the insulation of the cables 4 3 Stay clear of fan blades belts pulleys and other parts that can cause injury 4 4 Check the polarity of the battery posts The POSITIVE POS P battery post usually has a larger diameter than the NEGATIVE NEG N post 4 5 Determine which post of the battery is grounded connected to the chassis If the negative post is grounded to the c...

Страница 5: ... charged internal battery will read 100 Charge the internal battery if the display shows it is under 85 2 To reduce the risk of electric shock unplug the unit s charging cable from a USB or wall charger before attempting any maintenance or cleaning Simply turning off the controls will not reduce this risk 3 When charging the internal battery work in a well ventilated area and do not restrict the v...

Страница 6: ...al part of the frame or engine block 5 For a positive grounded vehicle connect the NEGATIVE BLACK clamp from the jump starter to the NEGATIVE NEG N ungrounded post of the battery Connect the POSITIVE RED clamp to the vehicle chassis or engine block away from the battery Do not connect the clamp to the carburetor fuel lines or sheet metal body parts Connect to a heavy gauge metal part of the frame ...

Страница 7: ...vary based on the mobile device s battery size and the charging port used NOTE Most devices will charge with either USB port but may charge at a slower rate 4 When finished using the USB port disconnect the charging cable from your mobile device and then disconnect the charging cable from the unit Slide the ON OFF switch to the OFF position 5 Recharge the unit as soon as possible after each use NO...

Страница 8: ... vehicle Check connections Verify the charge level of the jump starter is at least 40 Do not attempt to jump start your vehicle more than three consecutive times If the vehicle still does not start consult a qualified service technician When cable is connected only to the battery Solid Red LED Green LED off beeps once per second The vehical battery voltage is lower than 10 5V User can connect to j...

Страница 9: ...O NOT SHIP UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION RMA number from Customer Service at Schumacher Electric Corporation When returning an item place the original package into a shipping carton If you received an emailed label from Schumacher please print the label and tape it to the carton Only ship via insured ground service with a tracking number Return shipping charges are the ...

Страница 10: ...nit is resold through an unauthorized retailer Manufacturer may void this Limited Warrantyifa warrantyvoidifremoved labelisremovedfromtheproduct Manufacturer makes no other warranties including but not limited to express implied or statutory warranties including without limitation any implied warranty of merchantability or implied warranty of fitness for a particular purpose Further Manufacturer s...

Страница 11: ... claims This warranty is not transferable Send warranty card only DO NOT SEND UNIT TO THIS ADDRESS FOR REPAIR Mail this card to Schumacher Electric Corporation 801 Business Center Drive Mount Prospect IL 60056 2179 Name________________________________________________________________________________ Street address_________________________________________________________________________ City________...

Отзывы: