955-0002_v3.3, Rev-B
COPYRIGHT © 2012 RED.cm, Inc.
133
133
NETWORK
If the Gigabit Ethernet port is used, additional settings are required. Each camera or device requires a
unique IP ADDRESS. For simple camera-to-camera communication via Ethernet, both cameras need to
be in the same sub-net.
Use the same sub-NETMASK and GATEWAY addresses and the first three groups of the IP address
need to be the same.
In the example below, two cameras two cameras are assigned to the group “3D RIG.” Note the IP
Addresses.
Master
Slave
DHCP
If a DHCP-server is available in the
communications network the DHCP option can
be checked and the camera will obtain an IP
Address, Subnet Mask and Gateway address
automatically from the DHCP -server.
C2C
If the camera-to-camera (C2C) check box is
checked, changes to the settings on this
camera will be sent out via the network as UDP
packets as a SET command (Which then sets
the property on other cameras). SET commands
sent to this camera will not be propagated.
EXT
If the EXT check box is checked this camera
can be controlled via TCP/IP from an external
device.
IP Address
Permits the user to adjust the camera’s static IP
address.
Netmask
Permits the user to adjust the Subnet Mask
address.
Gateway
Permits the user to adjust the Gateway address.
Содержание EPIC-M
Страница 1: ......
Страница 243: ...COPYRIGHT 2012 RED com Inc 955 0002_v3 3 Rev B 242 242 242 242 CAMERA BRAIN DIMENSIONS Front View ...
Страница 244: ...955 0002_v3 3 Rev B COPYRIGHT 2012 RED cm Inc 243 243 Side View ...
Страница 245: ...COPYRIGHT 2012 RED com Inc 955 0002_v3 3 Rev B 244 244 244 244 Top View Bottom View ...
Страница 246: ...955 0002_v3 3 Rev B COPYRIGHT 2012 RED cm Inc 245 245 Back View ...
Страница 247: ...COPYRIGHT 2012 RED com Inc 955 0002_v3 3 Rev B 246 246 246 246 APPENDIX M RESOLUTION CHART ...
Страница 248: ...955 0002_v3 3 Rev B COPYRIGHT 2012 RED cm Inc 247 247 APPENDIX N MENU MAPS ...