A-3
INSTALLATION
A-3
EX350ie (CE) (RED-D-ARC)
LN-15 Connection Instructions
• Turn the EX350ie (CE) power switch "off".
• Connect the electrode cable to the output terminal of
polarity required by electrode. (See Figures below)
• Set the meter polarity switch on the front of the EX350ie
(CE) to coincide with wire feeder polarity used.
LN-25 Connection Instructions
• Turn the EX350ie (CE) power switch "off".
• Connect the electrode cable to the output terminal of
polarity required by electrode. Connect the work lead to
the other terminal.
• LN-25 with Remote Control options can be used with the
EX350ie (CE). The 6-Pin (K444-1) and 14-pin (K444-2)
remotes can be connected directly to the 6-pin & 14-pin
MS-style connector. The 42 Volt Remote Voltage and
Output Control (K624-2) Kit can be connected to the
EX350ie (CE) 14-pin MS-style connector using Remote
Control Cable assembly K627- [ ]. LN-25s with a K431-1
remote kit can be connected to the EX350ie (CE) 14-pin
MS-style connector using a K432 cable and K876
adapter. (See connection diagram S19899). Or the K432
cable could be modified with a K867 Universal Adapter
Plug (See connection diagram S19405) to connect it to
the EX350ie (CE) 14-pin MS-style connector.
LN-742 Connection Instructions
• Turn the EX350ie (CE) power switch "off"
• Either a K591 or a K593 Input cable assembly is
required to connect the LN-742 to the EX350ie
(CE).
• Connect the control cable from the LN-742 to the
14-pin MS-style connector.
• Connect the electrode cable to the output terminal
of the polarity required by electrode. Connect the
work lead to the other terminal.
• Set the meter polarity switch on the front of the
Invertec to coincide with wire feeder polarity used.
The wire feeder will now display the welding volt-
age.
• If a remote control such as K857 is to be used with
the LN-742, the remote can be connected directly
to the 6-pin MS-style connector on the front of the
EX350ie (CE) or use a K864 adapter to connect the
LN-742 and the remote to the 14-pin MS-style con-
nector.
Cobramatic Connection Instructions
• Turn the EX350ie (CE) power switch "off"
• Connect the control cable from the Cobramatic to
the 14-pin MS-style connector.
• Connect the electrode cable to the output terminal
of the polarity required by electrode. Connect the
work lead to the other terminal.
• Set the meter polarity switch on the front of the
Invertec to coincide with wire feeder polarity used.
• If a remote control such as K857 is to be used
with the Cobramatic, the remote can be connected
directly to the 6-pin MS-style connector on the front
of the Invertec or use a K864 adapter to connect
the cobramatic and the remote to the 14-pin MS-
style connector.
CONNECTION OF WIRE FEEDERS TO EX350ie (CE)
Wire feeders other than these listed may be used pro-
vided that the auxiliary power supply capacity of the
EX350ie (CE) is not exceeded. K867 Universal
Adapter Plug may be required. See connection dia-
gram S24985 on page F-4.
REMOTE CONTROL OF INVERTEC
Remote Control K857, hand Amptrol K963 and Foot
Amptrol K870.
uNDERCARRIAGE MOuNTINGS
14.79
12.44
3.44
21.60
27.82
5.50
10.00
MOUNTING HOLE LOCATIONS
M19527
13.10
1/4-20 NUT (4 PLACES)
NOTE: MOUNTING SCREWS CA
4/01
N NOT PROTRUDE MORE THAN
0.5 INCHES INSIDE THE MACHINE.
11.84
3.50
Work
Clamp
Electrode Cable
Electrode Cable
Electrode Cable
Work
Clamp
Work
Clamp
wire feeder
K1870-1
wire feeder
K1870-1
RANGER 8
SAE 400 WITH CV ADAPTER
ENGINE DRIVEN WELDERS
WITH WIRE FEED MODULE
(LOCAL MODE AND CV ADAPTER)
CV250
CV300
CV400
CC POWER SOURCE
Output Terminals
Always Hot.
Output Terminals
Always Hot.
Output Terminals
Always Hot.
Order K484 Jumper
Plug Kit.
Electrode Cable
Work
Clamp
semiautomatic
semiautomatic
semiautomatic
semiautomatic
wire feeder
K1870-1
wire feeder
K1870-1
wire feeder
K1870-1
CV655, DC400, DC600,
DC655, V350-PRO,
RANGER 9, RANGER 300 DLX
COMMANDER 300
COMMANDER 500
RANGER 2V35050
RANGER 305G
Output Terminals
Output Terminals
Always Hot.
Always Hot.
Power source contactor
Power source contactor
switch must be in the
switch must be in the
"ON" position or use a
"ON" position or use a
K848 Junper Plug Kit.
K848 Junper Plug Kit.
ACROSS THE ARC MODEL
EX350ie (CE)
TWIST-MATE
CONTROL CABLE MODEL
Electrode Cable
EX350ie (CE)
Содержание EX350ie
Страница 33: ...RED D ARC EX350ie CE P 584 P 584 PARTS LIST FOR Red D Arc EX350ie CE ...
Страница 41: ...RED D ARC EX350IE CE NOTES ...
Страница 42: ...11 10 2010 RED D ARC EX350IE CE P 584 D P 584 D Base Assembly 4A 4A 5A 5A 5B 5B 5C 5C 4B 4B 4C 4C 4 4 3 3 1 1 ...
Страница 49: ...RED D ARC EX350IE CE NOTES ...
Страница 52: ...RED D ARC EX350IE CE NOTES ...
Страница 53: ...NOTES EX350ie CE RED D ARC ...