The LED setting indicator will flash to indicate the setting selected as follows:
3.
LUX
Rotate the dial to control the ambient light level at which the sensor will allow the lamps to switch on. This range from
two lux minimum (fully anti-clockwise) to only switch on when very dark, through to 2000 lux maximum (fully clockwise)
to always switch on regardless of ambient light. Note that the fully clockwise setting should be used to check functionality
on initial installation.
No. of Flashes Setting Length
1
10 seconds
2
1 minute
3
2 minutes
4
5 minutes
5
8 minutes
6
10 minutes
7
15 minutes
8
20 minutes
9
25 minutes
10
30 minutes
Ratings
Power supply
220-240V AC 5/60Hz
Transmission Power <10mW
Rated Load
1200W
Power Consumption 0.9W approx.
Fault Finding
If you are experiencing a problem please check through the following before making contact with our Customer Services
Department:
Fault - Load does not come on
•
Check to see if the live supply to the circuit is working.
•
If the supply & wiring are good, check the LUX setting. Increase the LUX level setting to allow the sensor to turn on at
a higher ambient light level (rotate dial clockwise).
Fault - Load does not go off
•
Ensure that the area is left unoccupied for longer than the selected timer setting.
•
Make sure that the sensor is not adjacent to circulating air, heaters or lamps.
•
If the unit “false triggers” reduce the DISTANCE level to narrow the area of detection (rotate dial anti clockwise).