Specification

• 

220-240V

• 

13.5W

• 

64pcs of 2835 SMD LED

• 

4000K Colour temperature

• 

1150 Lumen output

• 

120° Beam angle

• 

>82 Ra

• 

3 Year guarantee

Installation Instructions 

1.

 Remove the diffuser & trim from the base by rotating anti-

    clockwise to unlatch then pull away. 

2.

 Loosen the three gear tray retaining screws, rotate the gear 

    tray anti-clockwise to align the screw heads with the large 
    aperture of the keyhole slots and remove the gear tray from 
    the base. There is a retaining strap to assist with 
    installation. 

3.

 Prepare the mains supply cable and fixing points on the 

    chosen mounting surface ensuring it is able to retain the 
    weight of the luminaire. 

4.

 Pass the mains supply cable through the hole & grommet 

    provided in the base, position the base to the mounting 
    surface and secure using the screws provided. 

5.

 It is the installer’s responsibility to ensure the fixing points 

    and cable entry point are appropriately sealed to maintain 
    the IP54 rating. Silicone bathroom sealant or equivalent is 
    recommended.  

6.

 Route the mains supply cable to the terminal block on the 

    gear tray and terminate ensuring correct polarity is   
    observed.

7.

 Secure the supply cable using the clamp provided in the 

    base. 

8.

 Refit the the gear tray and secure by retightening the 

    screws. 

9.

 Refit the diffuser and trim by placing over the base and 

    rotating clockwise until it locks into position. 

10.

 Reconnect power supply and check for correct operation. 

Note: Luminaires fitted with electronic ballasts are exempt 

from insulation resistance tests as this may cause damage to 

the ballast. 

Description of Microwave Sensor

The microwave sensor option offers presence detection 

to provide automatic control of lighting loads. It 

is installed inside the luminaire so does not affect 

external aesthetics or IP Rating. Manual adjustments 

on the sensor allow it to be individually tailored to suit 

your application.  

Positioning 

 The luminaire and the detector should be sited so that the 

   occupants of the room fall inside the detection patterns 
   shown in the appropriate diagram on page two.

 The diagram is based on a ceiling mounting height of 2.5m.  

Note that the lower that the sensor is installed, the smaller the 

detection range will be. 

 If wall mounted, the detection zone will vary depending on 

   the surroundings but vertical reach will be at least 10m.

 Both the areas closest to and vertical to the sensor will have 

   the highest sensitivity.

14W LED Slimline 
POLO Bulkhead with 

Microwave Sensor 

Installation 

Instructions p.1

Отзывы: