Understanding The Controls
Referring to Fig. below.
Setting The Controls
1.
Put the Lux control knob to daylight ( ) position, turn the wall switch on and wait half a minute for the control circuit
to stabilize. At this stage ensure that the TIME control knob is set at minimum duration time (-) position. The
Bulkhead light will now switch on and remain on for about 30 seconds (within 60 seconds).
2.
Direct the Sensor towards the desired area to be scanned by adjusting the PIR Sensor.
3.
Have another person move across the center of the area to be scanned and slowly adjust the PIR Sensor until the unit
sensors the presence of the moving person, causing the lamp to switch on. (refer Fig 1B).
4.
Adjust time control to required setting.
5.
To set the Lux level at which the lamp will automatically switch “on” at night, please turn the LUX control knob from
daylight to night, if the lamp is required to switch on earlier, e.g. Dusk, wait for the desired environment light level,
then slowly turn the LUX control knob towards the daylight ( ) while someone walks across the center of the area
to be detected. When the lamp switches on, release the LUX control knob. You may need to make further adjustments
to achieve your ideal light level setting.
IMPORTANT 1.
To avoid dust build-up and ensure proper functioning of the global lamp, wipe the sensor lens lightly with
a damp cloth every 3 months. But never modify the unit, there are no user serviceable parts inside.
2. Before touching the lamp or replacement of the bulb, please switch off first and then let it cool.
3. Any replacement of bulb, please switch power off.
Energy Saving Bulkhead
with PIR
Installation Instructions P.3
For models: LF13PIR
T:
0800 195 0006
F:
0870 043 3946
E:
www.redarrowtrading.com
Guarantee
This product is guaranteed for a period of 1 year from the date of purchase. The guarantee is invalid in the case of improper use, tampering, removal of the Q.C. date label, installation in
an improper working environment or installation not according to the current edition of the I.E.E. Wiring Regulations (BS7671). The guarantee is also invalidated if the luminaire has
been Mega tested. Should this product fail during the guarantee period it will be replaced free of charge, subject to correct installation and return of the faulty unit. We do not accept
responsibility for any installation costs associated with the replacement of this product. We reserve the right to alter specifications without prior notice.
Product complies with
all relevant European
standards
Product is suitable for
mounting on flammable
material
F
ADJUSTING THE DURATION TIME:
The length of time that remains switched on
after activation can be adjusted from (10±5) seconds to (4±1) minutes. Rotating the
TIME knob from (+) to (-) will reduce the duration time.
NOTE:
Once the light has been triggered by the PIR Sensor any subsequent detection
will start the timed period again from the beginning.
ADJUSTING THE LUX CONTROL LEVEL:
The Lux control module has a built-in
sensing device (photocell) that detects daylight and darkness. The ( ) position denotes
that the Bulkhead light can work at day and night, and the ( ) position only work at
night. You can set to operate the unit at the desired level by adjusting the LUX knob.
Red Arrow Trading
Elsworth House, Herries Road South, Sheffield,
S6 1QS
PRN WEE/BJ1331XR