LED Bulkhead with PIR
Installation Instructions P.1
T:
0800 195 0006
F:
0870 043 3946
E:
www.redarrowtrading.com
This installation must be carried out by an electrician. This light is constructed and tested to
IP44 and suitable for outdoor use. Please read these instructions carefully before installation.
Leave a copy for the user/maintenance engineer for future reference. Never modify the unit,
there are no user serviceable parts inside. It is not suitable for use with dimmer switches.
Install in accordance with I.E.C Wiring Regulations.
For models: LF13LEDPIR
Positioning the Unit
When selecting the mounting position, take into
account the following points:
1.
The sensor is designed for optimum performance
when mounted 2.5 metres above ground level.
2.
Avoid positioning close to trees or shrubs which
may cause false triggering during wet, windy
weather.
3.
Avoid pointing at or positioning close to heat
sources such as Boiler flu’s or heat extraction units,
which may cause false triggering.
4.
Avoid pointing at bright lights as unit will not
function when you set lux control level to dark.
5.
Avoid mounting near strong electromagnetic
sources, which may cause false triggering.
6.
The sensor is most sensitive to movement across the
detection area as opposed to directly towards or
away from the unit. Position the unit to point across
flow areas.
Specification
•
Wattage: 12 x 0.5W LED
•
LED: LG 5630
•
Life Expectancy: 20,000 hours
•
Supply voltage: 230V AC 50Hz
•
IP Rating: IP44
•
Material: Polycarbonate
•
Lumen Output: 428lms
•
Guarantee: Two years
Fitting the Unit
Before commencing any electrical work, ensure mains supply
cables are isolated by switching off and removing the relevant
fuse.
1.
Remove the diffuser by using a tool (such as screw driver)
and unscrew the screws (A), remove the terminal plate and
terminal block.
2.
Mark the mounting hole positions onto the wall. Drill and
plug the wall at the marked positions. Screw the light body
to the wall with suitable screws (supplied). Ensure that the
light body could not be out of shape.
3.
Connecting the main power wires to the terminal block (see
the relative symbols), the wires must pass through the
rubber gasket. Note that screwing the earth-wire must use
the toothed washer).
4.
Re-fit the terminal block and plastic plate (screw A).
5.
Re-fit the light cover by hand (without tools).
Diagram A
After finishing the fitting operation, you can adjust the
detection area and working state of the PIR detector.