background image

EnduraLED Polycarbonate 

Floodlights with PIR
Installation Instructions P.2

For models:  FLSMDPC10BOPIR, FLSMDPC20BPIR, 
FLSMDPC30BPIR, FLSMDPC50BPIR

Red Arrow Trading

Elsworth House, Herries Road South, Sheffield, 
S6 1QS

T:

 0800 195 0006     

F:

  0870  043  3946      

E:

 [email protected]      

www.redarrowtrading.com

PIR Sensor Control

Delay Settings:

• 

Delay time adjustable between 10 seconds - 5 minutes (5 seconds - 1 minute adjustable)

• 

Maximum physical adjustable angle of 270°.

• 

When the light is on, product will reset delay time and keep the light on when detected new signal. 

• 

When the light is off, it requires four seconds to re-stabilise. 

Detection Illumination Settings:

• 

Detect environment illuminance range 2-2000lux.  

• 

Max adjustable angle of 270°. 

Detection Distance Settings:

• 

Detect distance is maximum eight metres adjustable.

• 

Max adjustable angle of 270° (physical).

On the rear of the sensor are dials:

1. 

Lux - Provisionally turn the control fully to the moon symbol, in this setting the sensor is inactive during daylight. At 

    dusk, when the light level is at the desired level, adjust the dial towards the sun symbol until the floodlight turns on.

Note: This fitting does not have a walk test facility. Even with the dial turned fully clockwise, the light may not switch on 

during bright conditions. 

2. 

Time - Turn the dial fully anti-clockwise, the floodlight will stay on for five seconds. Turn the dial fully clockwise, the 

    floodlight will stay on for six minutes.   

3. 

Sensitivity - Turn the dial fully anti-clockwise for a one metre detection distance. Turn the dial fully clockwise for a 

    detection distance of eight metres. 

1.1.    

Switch on power supply, the sensor will stabilise for 15 seconds. 

1.2.    

The lamp will light on and off twice automatically then default to sensor mode. When the following two conditions 

          occur simultaneously the lamp will be lit:

1.2.1. 

Ambient light is lower than the setting value (LUX).

1.2.2. 

Movement of a live body or warm object within the detection area. 

2.       

Manual override (pulse override). 

2.1.    

Turn off the switch then turn on quickly, make sure the interval time is shorter than six seconds. 

2.2.    

The lamp will switch to normal lighting mode enabling continuous lighting without the use of the sensor function  

          until user switches off. 

Note: The sensor mode and normal lighting mode could be cyclically switched, if the power-off time is over ten seconds, 

the sensor will default to the sensor mode again when in a power-on state. 

Guarantee

This product is guaranteed for a period of two years from the date of purchase. The guarantee is invalid in the case of improper use, tampering, removal of the Q.C. date label, installation 
in an improper working environment or installation not according to the current edition of the I.E.E. Wiring Regulations (BS7671). The guarantee is also invalidated if the luminaire has 
been Mega tested. Should this product fail during the guarantee period it will be replaced free of charge, subject to correct installation and return of the faulty unit. We do not accept 
responsibility for any installation costs associated with the replacement of this product. We reserve the right to alter specifications without prior notice.

Product is suitable for 
mounting on flammable 
material

 

Product complies with 
all relevant European 
standards

PRN WEE/BJ1331XR

Attention:

Adjust the three function dials with caution to avoid damage. 

Отзывы: