RectorSeal CLEAN CHECK Скачать руководство пользователя страница 2

The Clean Check

®

 Extendable Backwater  

Valve is designed for easy re-installation.  
To properly re-seat the valve, slowly lower 
the inner assembly back into the outer 
riser pipe and rotate it until you feel the 
unit drop into place. The notch in the  
upper collar should now be lined up with 
the notch in the outer riser pipe. 

Important:

 Correct alignment of the 

notch in the upper collar and the notch  
in the outer riser pipe is necessary for  
correct repositioning of the inner assembly.

 
 
 

 

 

After seating the inner riser assembly 
properly, hand tighten the thumbscrew 
until it re-seats against the inside wall of 
the outer riser pipe. Be certain the thumb-
screw is NOT resting on the top of the 
larger outer riser pipe. The flat side of  
the flapper should be resting, in the  
closed position, on the building side  
of the valve body.

Replace the threaded cover plug.

Using the finger hole provided above  
the thumbscrew of the upper collar,  
extract the inner riser assembly. 

Clean any debris  
from the flapper, inner  
riser assembly, and the  
in ground valve body. 

Inspect the flapper  
for any deterioration  
or damage caused by  
the harsh environment  
in which it operates. If  
deterioration is present, 
replace the flapper  
(they are available from  
your local plumbing  
contractor or wholesale  
supply house.)  
 
For additional   
availability, contact:
RectorSeal  
Customer Service at  
800-231-3345 for a 
local source.

Upper Collar

Flapper Assembly

Inner Riser Assembly

 Flapper 

Outer Riser  

Pipe Notch 

             

Upper Collar  

Notch

CHECK

®

CLEAN

EXTENDABLE BACKWATER VALVE

MAINTENANCE GUIDE

Thumbscrew  

The following steps will guide your plumber 
through a proper inspection of your Clean 
Check

®  

Extendable Backwater Valve. 

Locate the Clean Check

®

 cover. It has been 

placed outside your building, between the
sewer lateral cleanout and the building. 

Remove the threaded cover plug by  

 

unscrewing it to expose the upper collar of  
the inner riser assembly.

Loosen, but do not remove, the stainless steel 
thumbscrew located inside the upper collar.

Note the locations of the thumbscrew and  
opposing notch. There are two notches:  
one in the outer riser pipe  
and one in the upper collar.  
This will be necessary for  
correct repositioning  
of the inner riser   
pipe during  
re-installation.

◄Clean Check

®

 cover

◄ 

Upper Collar

 

Outer riser

Sewer lateral cleanout 

Notch 

Threaded Cover Plug

Finger Hole 

Maintenance Procedure

Outer Riser Assembly  

◄ Outer Riser 

 

       Assembly

NOTE: Harmful bacteria are present in sewer lines.  We recommend that you contact your local health district for proper sanitary precautions.  

◄ Upper Collar

◄ Inner Riser Pipe