Operating Your Grill
Settings Button:
Press and hold the setting button to access the adjustable parameters menu. Short presses
of the settings button will scroll through the adjustable parameters. Pressing and holding the settings button
will exit the adjustable parameters menu.
Test Mode:
With grill OFF, press and hold the Settings Button to enter the Adjustable Parameters Menu.
Enter Test Mode from either of the four screens AUG, OFS, PrA, or PrB by pressing the Power Button. Each
additional press of the Power Button will advance you through the 8 Test Mode screens. The last screen is
the BYE screen. While on the BYE screen, press the Settings Button to return to the adjustable parameters
screen then press and hold the Settings Button and your grill’s controller will return to the OFF state.
Adjustable Parameter 1: Min Feed Rate
- Min Feed Rate
is the minimum rate that the auger is allowed to feed fuel to
the fire pot, regardless of Set Point. Decreasing the value will
allow the grill to achieve lower temperatures but will increase
the risk of flame-outs. Increasing the value will prevent losing
fire but will limit your ability to maintain low temperatures
on hot, sunny days.
Note: Changing this does not change the
auger speed. The auger speed is constant.
Adjustable Parameter 1 controller will display AUG.
Additionally, the current auger minimum feed rate will be
displayed as a number. Turning the Temperature Control
Knob clockwise will increase, and turning counterclockwise
decrease, the value within the range of 5 - 250. (Factory
preset: 30)
Adjustable Parameter 2: Temperature Offset
- Your
grill has been precisely calibrated at our facility, but the
Temperature Offset allows you to customize how your
controller will operate. Should you choose to rely on a
secondary temperature probe, you can use the following
process to recalibrate your Smart Grill Technology Controller.
Adjustable Parameter 2 will display OFS.
Additionally, the current temperature offset percentage
value will be displayed. Turning the Temperature Control
Knob clockwise will increase, and turning counterclockwise
decrease, the value within the range of -25.0 to 25.0.
(Factory preset: 0)
Due to varying qualities of pellet brands, we give you the ability to adjust your minimum feed
rate downward in the event that your grill is running hot at lower temperatures. However, if you
experience a sudden loss, followed by an immediate increase in grill temperature, then your grill
has experienced a flame out and will automatically relight. This signifies that your minimum feed rate
was adjusted too low and needs to be increased.
Adjustable Parameter 1
Adjustable Parameter 2
Probe A Calibration
Probe B Calibration
AUG
IGN
PrA
PrB