Malfunctions
7
BAL_Speedgate_slide_EN_1V0_REC_102-905401041
19 / 26
7
Malfunctions
7.1
Fault Finding
During normal operation, the main control logic GC01 displays a collection of messages regarding the
normal status or the fault conditions. To read the messages displayed by the GC01 is the first check
to do in case of failure of the Speedgate Flap
Symptom
Check
Action
Panels do not drive
Check mains input voltage and
24 VDC supply on logic boards
Replace transformer
Fuses on all three logic boards
Replace as required
Increase back-off sensitivity
If F1 fuse has blown motor may
be permanently damaged
Check functionality of all the lo-
gic boards on each electrical
plate, especially MB01 drive
cards
Re Flash Firmware
Perform a re learn
Replace as required
Card reader inputs
Remove card reader connec-
tions and link across the inputs
Photocells, perform diagnostic
test using GC01 to check that all
the photocells are working
Replace faulty photocell(s) if re-
quired
Check brackets
Unit alarms
Battery back up
If fitted the cells may be in need
of replacement. If they are not fit-
ted the self-test function should
be disabled by changing the rel-
evant parameter Check looms.
Panels do not close after transit
Safety photocell
Replace if required
Panel(s) do not back off when
obstructed
Trimmer on MB01 drive card
Tune the obstacle sensitivity.
Replace MB01
Panel(s) pulses when in open or
close position
Trimmers on MB01 drive card
Tune the offsets.
Replace drive card if required
Panel(s) do not open and close
correctly
Trimmers on MB01 drive card
Launch the learning procedure.
Replace drive card if required
Encoders
Replace if required
Check encoder mounted cor-
rectly
Check looms
Check Mech setting
Panel(s) open and close very
fast.
Encoders, and encoder looms
Replace if required
Check encoder mounted cor-
rectly
Check looms
Check Mech Setting
Incorrect mechanism selected
Adjust on MB01 board