Security inspection according EN 16005
2
BAL_S20_EN_1V0_REC_121-006454590
11/ 33
Term according to DIN
EN 16005
Description
Main closing edge
Edge of a door wing, whose distance from the parallel opposing closing
edge or opposing surface determines the usable open width.
Opposing / counter clo-
sing edge
Closing edge formed by the main closing edge of opposing closing wing, a
fixed edge or a surface, against which the wing moves (i.e. frame, floor).
Secondary closing edge Every other closing edge of the door wing, which is not the main or oppo-
sing closing edge.
Protection during closing cycle
EN 16005 stipulates that a person must be detected from both sides of the door, on the whole travel
area of the doorset.
The reference body (700x300x200 mm) must be detected at any point of an area as wide as the
doorway and extending over a distance of 200 mm on both sides of the door axle.
Reference body
Solution:
▪
Outside: 3 x Ixio-DT3
▪
Inside: 1x Ixio-DT3 + 2x Ixio-ST
NOTICE
A combination sensor Ixio DT3 (Performance Level "d") must be used on
the inside of doors in escape routes and emergency exits.
Protection during opening cycle
EN 16005 covers also personal safety during the opening cycle.
Depending on the situation, the danger point can be safeguarded as follows while opening:
1. by finishing profiles and safety distances
2. by protective screens
3. by presence sensing device (Ixio-ST in the side panel area. One sensor per door leaf)
4. by limitation of leaf force
2.2
2.3