Figure 4.7 the wire for the 485 connecting
Connection details are shown in the table below:
Table4.7 definition of the 485 interface
PIN
DESCRIPTION
REMARK
1
R/T+
Connect to 485A of CTRL_INTERFACE
2
R/T-
Connect to 485B of CTRL_INTERFACE
4.5
Laser Control
The power supply of the fiber laser is powered by local and remote methods.
The local mode is controlled by the front panel START button, and the remote mode
is controlled by the REM_START signal line in the rear panel CTRL_INTERFACE.
The laser power setting and the light-emission enable control: the laser power
setting is controlled by the 0~10V analog signal on the rear panel, he light-emission
enable control is controlled by the LASER_EN signal line of CTRL_INTERFACE in
the rear panel. In addition, the output is controlled by the MOD_SW signal of
CTRL_INTERFACE in the rear panel