Beijing Reci Laser Technology Co., Ltd
User Guide for FSC1000, FSC1500
28
(4)
Set the laser power through the 0~10 analog signal.
(5)
Turn on the 24V laser enable signal (the light output power can also be
changed after the light is enabled).
(6)
Fast switching optical modulation output by modulation signal. (The red light
indicator automatically turns off when laser is emitted, and turns on when
laser is off)
4.7
Remote AD Model
4.7.1
Settings and Connections
Figure 4.9 the connecting for remote AD model
(1) Set the AD mode with the control software.
(2) The 24V laser enable signal is connected to pins 5 and 6 of the rear panel 16
PIN CTRL_INTERFACE.
(3) The 24V modulated signal is connected to pins 12 and 13 in the rear panel 16
PIN CTRL_INTERFACE.
(4) 0~10 analog signal to the rear panel 2 PIN analog interface.