background image

 

REBOTEC / 

BA-Nr.: 02.08.204/2021-01-A01

 

- 7 - 

EN 

10.  Product data 

  We  reserve  the  right  to  make  technical  develop-

ments  and  improvements  with  respect  to  the  de-
sign shown in this User Manual. 

  See 14. 

Characteristic 

Value 

1. 

User weight 

max. 130 kg 

2. 

Product weight* 

3.5 kg 

3. 

Total weight* 

4.0 kg 

Skin compatibility 

DIN EN 10993-1/-5 

*Without accessories. 

11.  Operation of the product 

Attention: Danger of falling!

 

  Observe the safety instruction (4). 

  Before use, it must be ensured that the product is 

in proper condition. 

  A stable position with no risk of slipping or tipping 

over must be ensured. 

11.1. 

Sitting down 

  The  user  must  position  themselves  as  close  as 

possible to the product. If necessary, they can ori-
entate or support themselves with their hands on 
the armrests. 

  If  this  is  not  possible  due  to  their  physical  limita-

tions, the user must seek the assistance of a com-
petent person. This can  be done with the  help of 
an assistive device. 

11.2. 

Getting up 

  To get up, the feet must be in contact with the floor. 

  Then, slightly shift your weight forward and slowly 

rise from the seat. 

  Do not lean your body too far forward to avoid the 

risk of falling. If necessary, the user must seek help 
to get up from the stool. 

12.  Care and maintenance 

12.1. 

Cleaning and care 

The  product  can  be  cleaned  using  a  mild 

conventional  cleaning  and  disinfecting 

agent. After cleaning, wipe the product with a clean, 
moist cloth and then wipe it dry with a dry cloth. 

  Do  not  use  scouring  agents  or  cleaning  agents 

with  aggressive  ingredients  (acids,  thinners),  as 
well as hard cleaning objects (brushes), as other-
wise  the  surfaces  may  be  damaged  or  deposits 
may form on the materials. 

  The product  is suitable for  machine cleaning and 

disinfection.  Please  observe  the  reprocessing  in-
structions (02.12.159). 

12.2. 

Maintenance 

  Wear and tear that is not recognised in time and / 

or  improper  handling,  as  well  as  irregular  or  no 
maintenance may result in accidents. 

For  safety  reasons,  the  product  must  be 
professionally  maintained  at  least  once  a 

year

  Check product for visible damage 

  (cracks, breakage, loose parts) 

  Check stability before use 

  If you have any questions concerning the mainte-

nance of the product, please contact an authorised 
dealer or a medical and healthcare supplies store. 

  In  the  event  of  damage  and/or  repairs,  contact 

your authorised dealer immediately. 

  Never  attempt 

any

  unauthorised  modifications  or 

conversions to the product. These may impair the 
safety  and  proper  functioning  of  the  product. 

In 

such cases, REBOTEC will not assume any lia-
bility

  Only use OEM spare parts for repairs. See 6. 

  Please note section 13 and 7. 

  After maintenance or repair work has been carried 

out, we recommend you clean the product before 
using it again. 

  Please  observe  the  maintenance  instructions 

(02.11.163). 

 

Содержание 363.00.20

Страница 1: ...ax 49 0 5431 9416 66 Web www rebotec de BA Nr 02 08 204 2021 01 A01 Email info rebotec de Read this User Manual before using the device for the first time and keep it at hand for the user as well as f...

Страница 2: ...ameplates 4 4 Safety instructions 4 5 Incident reporting 5 6 Warranty 5 6 1 Complaint 5 7 Reuse lifetime 5 8 Scope of delivery 5 9 Setting up for use 5 9 1 Assembling the tube sets 5 9 2 Assembling th...

Страница 3: ...mities with limited or eliminated mobility and muscle strength and or damage to the vestibular functions or tendency to fall due to other causes while at the same time maintaining a sufficiently stabl...

Страница 4: ...s Unique Device Identifier Data GTIN LOT SN year of man ufacture Medical device label This product is a medical device 4 Safety instructions Please observe the following safety in structions Before us...

Страница 5: ...mage use the original packaging if possible The Infection Protection Act must be complied with Please make sure that the product does not pose a risk of infection when returned Enclose the information...

Страница 6: ...There is a risk of breakage if the bending stress is too high Place the product on a flat surface Position the first armrest 1 at the seat plate 2 Hold the armrest in position 3 with slight counter p...

Страница 7: ...ng a mild conventional cleaning and disinfecting agent After cleaning wipe the product with a clean moist cloth and then wipe it dry with a dry cloth Do not use scouring agents or cleaning agents with...

Страница 8: ...59 Reprocessing Instructions 02 11 163 Maintenance Instructions 4 456 00 25 Foot cap 5 201 90 28 Adjustment clip 6 463 90 40 Union nut 7 442 00 25 End plug 8 463 90 20 Armrest 9 463 90 60 Clip 284 00...

Страница 9: ...max 763 b Width 525 c Depth 545 d1 Seat height min 415 d2 Seat height max 565 e Spacing of the armrests 445 f Seat width 330 g Seat depth 330 bxc Floor space 525 x 545 Dimensions and weights may vary...

Страница 10: ...REBOTEC BA Nr 02 08 204 2021 01 A01 10 EN...

Страница 11: ...REBOTEC BA Nr 02 08 204 2021 01 A01 11 EN...

Страница 12: ...OTEC BA Nr 02 08 204 2021 01 A01 12 EN REBOTEC Rehabilitationsmittel GmbH D 49610 Quakenbr ck Artlandstr 57 59 Telephone 49 0 5431 9416 0 Fax 49 0 5431 9416 66 Web www rebotec de Email info rebotec de...

Отзывы: