RealFyre VR-2A Скачать руководство пользователя страница 2

Robert H Peterson Co. Model: VR-2A

9-9-20 Page 2

ROOM

LCD - Liquid Crystal Display

TEMP

1

2

3

SET

4

5

6

1. 

DISPLAY   

Indicates CURRENT room temperature .

2. 

0

F OR 

0

C  

Indicates degrees Fahrenheit or Celsius.

3. 

FLAME  

Indicates burner/valve in operation.

4. 

ROOM   

Indicates remote is in THERMO operation.

5. 

TEMP    

Appears during manual operation.

6. 

SET  

 

Appears during time of setting the desired  

 

 

 

temperature in the thermo operation.

SETTING °F / °C SCALE

The factory setting for temperature is 

°

F.  To change this setting to 

°

C press the ON/HI key and 

the LO/OFF key on the transmitter at the same time this will change from 

°

F to 

°

C.  Follow this 

same procedure to change from 

°

C  back to 

°

F.

  

TEMP

TEMP

TEMP

OFF OPERATION

3UHVVDQGKROGWKH/22))NH\XQWLOWKHDSSOLDQFHÀDPHUHDFKHVWKH
GHVLUHÀDPHKHLJKWRUFRPSOHWHO\VKXWVRII'XULQJWKLVWLPHWKH/&'

screen will show LO, after 3 seconds the LCD screen will default to 
display room temperature and the word TEMP will show. 

MANUAL FUNCTION

To operate the system in the manual “MODE” do the following.

ON OPERATION

3UHVVDQGKR,NH\XQWLOWKHDSSOLDQFHÀDPHWXUQV21DQG
UHDFKHVWKHGHVLUHGÀDPHKHLJKWRULVDWIXOORQ'XULQJWKLVWLPHWKH

LCD screen will show HI, after 3 seconds the LCD screen will default to 
display room temperature and the word TEMP will show. (Flame icon will 
appear on LCD screen in manual on mode)

TEMP

SET

ROOM

TEMP

THERMOSTAT FUNCTION

SETTING DESIRED ROOM TEMPERATURE

This remote control system can be thermostatically controlled when the 
transmitter is in the THERMO mode (The word 

ROOM must be displayed on 

the screen

).  To set the THERMO MODE and DESIRED room temperature,

 
Press the 

MODE

  key until the LCD screen shows the word 

ROOM

, then the 

remote is in the thermostatic mode.

Press and hold the 

SET

 key until the desired set temperature is reached. (By 

pressing and holding the set key the LCD screen set numbers will increase from 
45° to 99° then restart over at 45° ) Next release the 

SET

 key.  The LCD screen 

ZLOOGLVSOD\WKHVHWWHPSHUDWXUHIRUVHFRQGVDQGWKH/&'VFUHHQZLOOÀDVKWKH

set temperature for 3 seconds, then the LCD screen will default to display the 
room temperature.

f i r e - p a r t s . c o m

Содержание VR-2A

Страница 1: ...ervo motor or solenoid The circuit has reversing polarity software which reverses the positive and negative output of the receiver s battery power to drive the servo motor forward backward HI LO FLAME...

Страница 2: ...e system in the manual MODE do the following ON OPERATION 3UHVV DQG KROG WKH 21 NH XQWLO WKH DSSOLDQFH DPH WXUQV 21 DQG UHDFKHV WKH GHVLUHG DPH KHLJKW RU LV DW IXOO RQ XULQJ WKLV WLPH WKH LCD screen w...

Страница 3: ...never the ROOM TEMPERATURE varies a certain number of degrees from the SET TEMPERATURE This variation is called the SWING or TEMPERATURE DIFFEREN TIAL The normal operating cycle of an appliance may be...

Страница 4: ...osition where the ambient temperature inside the receiver case does not exceed 120 F NOTE Black Button Receiver Slide Button is used on Hearth Mount Applications Wire terminals Remote Receiver Receive...

Страница 5: ...ter the receiver emits the beep press the transmitter OFF button and release The receiver will emit several beeps indicating that the transmitter s code has been accepted into the receiver A microproc...

Страница 6: ...SHOOTING I RX HQFRXQWHU SUREOHPV ZLWK RXU UHSODFH V VWHP WKH SUREOHP PD EH ZLWK WKH UHSODFH LWVHOI RU LW FRXOG EH ZLWK WKH UHPRWH V VWHP 5HYLHZ WKH UHSODFH PDQXIDFWXUHU V RSHUDWLRQ PDQXDO WR PDNH VXUH...

Страница 7: ...ent and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device...

Отзывы: