10.)
After installing the conversion kit, verify the location of the
Pilot, Thermocouple and Igniter Pin using the illustration below.
Installing at Altitude
For installations at elevations above 2,000 ft., contact your local dealer or gas
supplier before installing because input rating should be reduced
approximately 4% for each 1,000 ft. above sea level. Refer to the National Fuel
Gas Code. Contact Real Flame for more information at 1-800-654-1704.
11.)
Note to installation technicians: Verify the manifold pressure by using a
3/8” flared T-junction at the location marked by the arrow below. Then, using
a digital manometer, verify that the pressure before the orifice is 7” W.C. Also
verify that the orifice spud has the 3.9mm stamp. This will allow you to verify
that the input rating of the appliance is correct.
NATURAL GAS CONVERSION
8
To Manometer
Igniter Pin
NOTE: Igniter housing removed for example only.
Thermocouple
.25”
Содержание Riverside C539LP
Страница 5: ...4 NATURAL GAS CONVERSION 4 Remove the existing LP orifice spud LP Orifice Spud...
Страница 7: ...6 NATURAL GAS CONVERSION 7 Re attach bellows CSST to new spud Bellows...
Страница 17: ...4 CONVERSION DU GAZ NATUREL 4 Orifice de patate LP...
Страница 19: ...6 CONVERSION DU GAZ NATUREL 7 Rattachez les soufflets CSST la nouvelle patate Soufflets...
Страница 29: ...4 CONVERSI N DE GAS NATURAL 4 Retire el intermediario de LP existente Intermediario de LP...
Страница 31: ...6 CONVERSI N DE GAS NATURAL 7 Vuelva a conectar el fuelle CSST al nuevo intermediario Fuelle...