RealFlame Riverside C539LP Скачать руководство пользователя страница 1

C539LP Riverside Fire Bowl NG Conversion Kit

Improper installation, adjustment, 

alteration, service or maintenance

can cause property damage 

personal injury, or loss of life.

Read the installation, operation 

and maintenance instructions 

thoroughly before installing or 

servicing this equipment.

 

!

!

IMPORTANT

WARNING

SAVE THESE INSTRUCTIONS

!

DANGER

If you smell gas:

  gas to the appliance.

2. Extinguish any open fl ame.

3. If odor continues, keep away from the appliance and 

immediately call your gas supplier or fi re department.

US

C

For Technical Support  Please Contact Real Flame® At: 1-800-654-1704

Содержание Riverside C539LP

Страница 1: ...n operation and maintenance instructions thoroughly before installing or servicing this equipment IMPORTANT WARNING SAVE THESE INSTRUCTIONS DANGER If you smell gas gas to the appliance 2 Extinguish an...

Страница 2: ...ire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit Th...

Страница 3: ...NATURAL GAS CONVERSION 2 1 Flip bowl upside down Place on a soft surface to avoid damaging the finish 2 Disconnect LP hose from valve...

Страница 4: ...NATURAL GAS CONVERSION 3 3 Disconnect bellows Corrugated Stainless Steel Tube CSST from burner base Bellows...

Страница 5: ...4 NATURAL GAS CONVERSION 4 Remove the existing LP orifice spud LP Orifice Spud...

Страница 6: ...d verify it is the correct number The sign 3 9mm should be on the end of the orifice spud 6 Slip sleeve over primary air opening See fig 1 Next screw the new NG orifice spud into the burner base See f...

Страница 7: ...6 NATURAL GAS CONVERSION 7 Re attach bellows CSST to new spud Bellows...

Страница 8: ...8 Attach NG hose to the input side of the valve 9 Attach quick disconnect to gas supply NATURAL GAS CONVERSION House Natural Gas Piping Shut off Valve Quick Disconnect Socket NG Gas Hose To Fire Bowl...

Страница 9: ...o the National Fuel Gas Code Contact Real Flame for more information at 1 800 654 1704 11 Note to installation technicians Verify the manifold pressure by using a 3 8 flared T junction at the location...

Страница 10: ...ure the fire bowl control knob is OFF Then turn the natural gas on at its source Spray leak solution on the valve connections paying particular attention to the areas indicated by the arrows If any bu...

Страница 11: ...ired height with the control knob Flames should be between 8 13 in height 1 Wearing heat resistant gloves position the burning long match or extended lighter near the side of the burner DO NOT lean ov...

Страница 12: ...avec le kit no par NOTES ______________________________________________________ _____________________________________________________________ _________________________________________________________...

Страница 13: ...l installation l op ration et des instructions de maintien fond avant stallation ou entretien de cet quipement IMPORTANT DANGER imm diatement votre fournisseur de gaz ou le service des incendies C S...

Страница 14: ...exactement un incendie une explosion ou la production de monoxyde de carbone peut causer des dommages mat riels des blessures corporelles ou la pertes de vie Le service d entretien qualifi est respon...

Страница 15: ...CONVERSION DU GAZ NATUREL 2 1 Retournez la bol de feu sur son c t Placez sur une surface souple pour viter d endommager la finition 2 D branchez le tuyau LP de la valve...

Страница 16: ...CONVERSION DU GAZ NATUREL 3 3 Soufflets D brancher le soufflet Tubes en acier inoxydable ondul CSST de la base de br leur...

Страница 17: ...4 CONVERSION DU GAZ NATUREL 4 Orifice de patate LP...

Страница 18: ...3 9 mm devrait tre sur l extr mit d orifice de patate 6 issez le gaine sur l ouverture a rienne princi ir fig Ensuite vissez la nouvelle patate d ifice N ans la base de br leur ir fig Gaine L ouvertu...

Страница 19: ...6 CONVERSION DU GAZ NATUREL 7 Rattachez les soufflets CSST la nouvelle patate Soufflets...

Страница 20: ...7 8 9 CONVERSION DU GAZ NATUREL Tuyauterie de Gaz naturel de Maison Soupape d arr t Prise de d connexion rapide Tuyau de Gaz NG Au Bol de Feu...

Страница 21: ...s installations une altitude sup revendeur local ou fournisseur de gaz avant l installation comme l valuation d entr e devrait tre r duite d enviro pour c dessu nat lu in 11 CONVERSION DU GAZ NATUREL...

Страница 22: ...sur le gaz naturel sa source Pulv riser la solution de fuite sur les connexions de valve en accordant une attention particuli re aux endroits indiqu s par les fl ches voir des bulles apr s plusieurs t...

Страница 23: ...cm de hauteur 1 En portant des gants r sistant la chaleur placez la longue allumette br lant ou briquet au du br leur Ne penchez pas la bol de feu en allumant 2 Tournez le bouton de commande de tour...

Страница 24: ...______________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________...

Страница 25: ...IMPORTANTE ADVERTENCIA GUARDE ESTAS INSTRUCCIONES PELIGRO Si siente olor a gas 1 Apague el artefacto 2 Extinguir cualquier llama abierta 3 Si el olor contin a mant ngase alejado del artefacto y llame...

Страница 26: ...observa es trictamente puede producirse mon xido de carbono incendio o explosi n causando da os materiales lesiones personales o p rdida de vidas La agencia de servicio calificada es responsable de la...

Страница 27: ...CONVERSI N DE GAS NATURAL 2 1 Gire la taz n de fuego sobre su lado Coloque sobre una superficie suave para evitar da ar el acabado 2 Desconecte la manguera de LP de la v lvula...

Страница 28: ...CONVERSI N DE GAS NATURAL 3 3 Desconecte el fuelle Tubos de acero inoxidable corrugado CSST de la base del quemador Fuelle...

Страница 29: ...4 CONVERSI N DE GAS NATURAL 4 Retire el intermediario de LP existente Intermediario de LP...

Страница 30: ...ea el n mero correcto El n mero 3 9mm debe estar en el extremo del intermediario 6 Deslice la manga sobre la abertura de aire primario Ver fig 1 Luego atornille el nuevo intermediario de GN en la base...

Страница 31: ...6 CONVERSI N DE GAS NATURAL 7 Vuelva a conectar el fuelle CSST al nuevo intermediario Fuelle...

Страница 32: ...de GN a la entrada de la v lvula 9 Conecte la desconexi n r pida al suministro de gas CONVERSI N DE GAS NATURAL Tubo de gas natural V lvula de cierre Conexi n de la desconexi n r pida Manguera de gas...

Страница 33: ...el del mar Consulte el C digo Nacional de Gas Combustible Contacte a Real Flame para obtener m s informaci n al 1 800 654 1704 11 Nota para los t cnicos de instalaci n Verifique la presi n del colecto...

Страница 34: ...nistro de gas natural Roc e la soluci n de fugas en las conexiones de la v lvula prestando especial atenci n a las reas indicadas por las flechas Si aparecen burbujas cierre el suministro de gas vuelv...

Страница 35: ...0 3 30 5 cm de altura te la llama a la intensidad deseada mediante la perilla de control 1 Usando guantes resistentes al calor coloque el f sforo largo encendido o encendedor de gas butano encendido p...

Страница 36: ..._______________________________________ _____________________________________________________________ _____________________________________________________________ ____________________________________...

Отзывы: