NATURAL GAS CONVERSION
NOTE: The normal manifold pressure for this converted appliance is 7” water column.
NOTE: The maximum inlet gas pressure for this unit is 10.5 in W.C. (2.61 kPa).
The minimum inlet gas pressure for this unit is 3.5 in W.C. (0.87 kPa).
Check for leaks at these locations
11. CHECKING FOR LEAKS
Make a leak check solution by mixing 1 part dishwashing soap
with 3 parts water in a spray bottle.
Make sure the fire bowl control knob is “OFF.” Then, turn the
natural gas on at its source.
Spray leak solution on the valve connections, paying particular
attention to the areas indicated by the arrows.
If any bubbles appear turn the natural gas off at its source,
reconnect and re-test. If you continue to see bubbles after several
attempts, disconnect the natural gas source and contact Real
Flame
® at 1-800-654-1704 for assistance.
If no bubbles appear after one minute, turn the gas
source “OFF”, wipe away solution and proceed to next
step.
10.)
Attach quick disconnect to gas supply.
House Natural Gas Piping
Shut-off Valve
Quick Disconnect Socket
NG Gas Hose
To Fire Bowl