7 ASSEMbLY, COMISSIONING AND INSTALLATION
7.1 Ambient conditions
Assembly is to be carried out in the following order.
If the pump has to be installed outdoors, then it is to be equipped with
protection against sunlight and weather influences.
When positioning the pump, ensure that sufficient room for access is
provided for all types of maintenance work.
Limit values for hose temperature and pressure
Tube Material
Min. Temp. (ºC)
Feed liquid
Max. Temp (ºC)
Feed liquid
Min. Temp (ºC)
Environment
Max.
Pressure (bar)
NORPRENE
-10
80*
-10
2
SOLVA
3
SILICONE
2
* At max. temperature, the life of tube is drastically reduced. Please contact authorized distributor for
applications with feed liquid temperature higher than 60 °C.
7.2 Commissioning
7.2.1 Testing prior to commissioning the pump
The following tests are to be carried out:
- Only switch the pump on if the front cover has been properly
attached.
- Check that the mains voltage is suitable for the motor.
- Check that the thermal overload protection (not included in the
delivery scope) corresponds to the value specified on the motor
type plate.
- Confirm that pump has been properly earthed.
- Connect the electric motor according to local applicable rules
and regulations. The electrical installation work must be carried
out by qualified personnel.
- Check that the optional electrical components are connected
and are working properly.
- Check whether the direction of rotation is correctly adjusted.
Содержание APY
Страница 1: ...Operating instructions APY Series Peristaltic pump ALL THE HOSE PUMP YOU LL EVER NEED...
Страница 25: ...25 25 Troubleshooting Spare parts End of life...
Страница 28: ...Operating instructions Peristaltic Pump APY Series 28 10 Spare parts 10 1 Spare parts exploded APY Model...
Страница 30: ...Operating instructions Peristaltic Pump APY Series 30 10 2 Spare parts exploded APY LAB Model...
Страница 33: ...33 12 Declaration of Conformity K t d d W Z Wz W d Wz Z W d D d W W W...
Страница 39: ...Operating instructions Peristaltic Pump APY Series 39...
Страница 40: ...AHQ IOM EN 0971 0521 www realaxpumps com ALL THE HOSE PUMP YOU LL EVER NEED...