Real Time Automation, Inc.
A
1-800-249-1612
460 Gateway Device Line
460EAV
Port 0 (T-Strip) RS485 & PWR 1
2
3
4
5
Pin Setting
GND
TX-
TX+
NC
PWR
Port 1 (DB-9) RS232
1
2
3
4
5
6
7
8
9
Pin Setting
NC
RX
TX
NC
GND
NC
NC
NC
NC
NC
= No connection
Appendix A: Jumper Configurations
1) To change port settings on the 460EDX Gateway use the following steps:
2) No cables should be connected to the Gateway unit. If this unit has been in use and you are making a
change, disconnect the power cable and any communications cables from the Gateway unit.
3) Remove the two small Phillips-head screws from each long side of the Gateway unit.
4) Remove the green T-Strip connector. Slide the cover off towards the ports. The jumpers are just behind
the ports.
5) Move the jumper shunts to reflect the desired settings.
6) Replace the Gateway unit’s cover. Replace the four screws. Replace the green T-Strip connector.
Only one RS232, RS422, RS485, or CAN port setting can be active at a time
for each unit. For example, a unit cannot have two ports set for RS232 or two
ports set for CAN.
NC
= No connection