15
TESTS TO BE CARRIED OUT BY INSTALLER
FAILURE PROCEDURE
A.
The pilot is burning
B.
Ensure that the wiring terminals on the gas valve are not loose.
C.
Check that the inlet and working gas pressure are correctly set.
ACCESSING PILOT
If, when the control knob is turned to the “ON” position and the remote switch is turned to
the “ON” position, the fire fails to ignite, check the following. (Allow 1 minute for the main
burner to ignite once turned on.)
Figure (1)
Remove the two glass panels, remove
the front panel, this is held in place by
two screws, one on each side.
Figure (2) Remove the two screws holding
the small bracket
•
Remove Hi/Lo knob (1).
•
Connect manometer to hi lo pressure point connection (3.)
•
Via Hi/Lo knob (1), adjust hi pressure to N.G 0.9 OR LPG 2.54.
Do not exceed these settings.
•
Replace Hi/Lo knob.(1) (Note: Lo pressure will automatically set when knob is replaced)
•
Check that flame height adjusts when Hi/Lo is turned.(1)
•
Check that there are no gas leaks from any of the fittings.
•
Explain to the customer how to turn the unit on and off (refer to page 14)