White Rogers Valve Used For

Electronic Ignition For 850 & 100

Modular Boxes.

Part Number: W0079

Dungs Valve used On 1400

Burner In 1800 Modular Box.

Part Number: DUBM 241221

Sparker and Sensor Fitted to all

Electronic Ignitions.

Part Number: GST0829985

Techrite Electronic Ignition

Module.

Part Number: TAIS00RISD5 

Techrite Power Flue Module used

on all Power Flue Models.

Part Number: TAISCPRI5DS

Regulator fitted to all Natural Gas

1400 Magiglo Burners.

Part Number: 2369

28

Содержание Hybrid 1000

Страница 1: ...ybrid fire boxes are approved to be installed as a zero clearance firebox and are designed to operate on Natural Gas and Propane LPG gases ONLY Approval Number GMK10099 Installed primarily as a decora...

Страница 2: ...has been installed in an outdoor setting 4 Limit of Liability The warranty provided under this warranty is limited to replacement or repair of the Real Flame Gas Burner only at our option To the exte...

Страница 3: ...erating if children or the infirm are in close proximity A safety screen is recommended if constant supervision is not possible It is recommended that a secondary guard complying with AS NZS2286 be in...

Страница 4: ...Frame Installation 12 Installation Check List 13 Lighting Testing and Failure Procedure 14 Flue Requirements Standard 15 Flue Requirements Power Flue Kit 16 Optional Power Flue 17 Introduction 17 Ins...

Страница 5: ...ector Size mm TPP N G C Mj Hr Natural Gas 3 x 1 85 0 75 kPa 39 ULPG 3 x 0 95 2 55 kPa 34 Hybrid 1500 Hybrid Signature 1500 Fitted with 1000 or 1000EI burner Gas Injector Size mm TPP N G C Mj Hr Natura...

Страница 6: ...ox is an electronic ignition system and as such electrical work is required Overall Dimensions in mm MODEL Size Inner Outer HYBRID 850 200 250 HYBRID 1000 250 300 HYBRID 1500 300 350 HYBRID 1800 300 3...

Страница 7: ...J J DIMENSIONS Hybrid 850 Left Hand Model Hybrid 850 Right Hand Model A B C D E F G H 920 950 450 570 165 335 230 150 I J K L M N O 400 120 50 10 50 520 350 7...

Страница 8: ...DIMENSIONS Hybrid 1000 Left Hand Model Hybrid 1000 Right Hand Model A B C D E F G H 920 1100 450 570 165 335 230 150 I J K L M N O 400 120 50 10 50 520 350 8...

Страница 9: ...L B M E O H 125 87 130 100 70 F C A D J I N G K B M E O H DIMENSIONS Hybrid 1500 Left Hand Model Hybrid 1500 Right Hand Model A B C D E F G H 1000 1600 450 500 190 370 215 300 I J K L M N O 330 120 5...

Страница 10: ...B M E O H 87 125 87 130 100 70 F C A D J I N G K B M E O H DIMENSIONS Hybrid 1800 Left Hand Model Hybrid 1800 Right Hand Model A B C D E F G H 1135 1900 450 500 190 370 215 435 I J K L M N O 330 120...

Страница 11: ...DIMENSIONS Hybrid 3300 Left Hand Model Hybrid 3300 Right Hand Model A B C D E F G H 1135 3400 450 500 190 370 215 435 I J K L M N O 330 120 50 10 50 450 635 11...

Страница 12: ...s are to be installed PRIOR to plasterboard Plasterboard is to be run past stud frame and up to fire opening terminating in square edge MODEL A B C D HYBRID 850 1020 1000 475 2100 HYBRID 1000 1020 115...

Страница 13: ...to the burner Position the unit ensuring the wiring loom and gas pipe are accessible Connect the twin skin flue or Optional Power Flue if supplied Install an AGA approved gas cowl ensuring the termin...

Страница 14: ...veral tries turn the switch to OFF and call your service technician or gas supplier TO TURN OFF GAS TO APPLIANCE 1 Turn off the remote wall switch LIGHTING MAIN BURNER TESTS TO BE CARRIED OUT BY INSTA...

Страница 15: ...cowl These notes must be read in conjunction with AGA code 601 Floor 0 mm Sides 25 mm Back 25 mm Top 100 mm Flue Outer 25 mm CLEARANCES A minimum of 3 6m flue is required to protrude 500mm above roof...

Страница 16: ...ical FLUE REQUIREMENTS Electrical Wiring between Fan Unit Kit 100mm Gas cowl Kit Fan Casing Kit Twin Skin Flue 150mm 200mm Optional for additional height if required Twin Skin Flue 100mm 180mm Baffled...

Страница 17: ...ed WIRING OF THE POWER FLUE All wiring for the power flue is carried out at the factory and plug connectors are fitted for easy installation The power supply for the power flue is via a 3 pin plug at...

Страница 18: ...floor ventilation 500mm ELECTRICAL SHOULD THE SUPPLY FLEX AT THE BACK OF THE FIREBOX BE DAMAGED A SPECIALLY PREPARED FLEX IS REQUIRED FOR REPLACEMENT CONTACT THE MANUFACTURER THE ON OFF WALL SWITCH MU...

Страница 19: ...the motor fits to or the 150 200 twin skin flue if required The flow arrow on the muffler is to be pointing up If a 1800 or 3300 unit is used the flue is 200mm 250mm WIRING see wiring diagram pages 1...

Страница 20: ...m clearance 250mm Minimum height 150mm 200mm twin skin flue optional for additional height Ensure there is adequate ventilation within this cavity to prevent motor over heating Baffle Height 980mm and...

Страница 21: ...21 TYPICAL POWER FLUE FRAMEOUT Fan Casing Pressure Differential Switch Motor Motor...

Страница 22: ...0mm x 200mm or 200 250mm flue extension 250mm min 900mm Min Distance Domestic 220mm 200mm or 300mm 500mm 25mm Flush Cowl termination Top Termination Flue Access Panel NOTE 1 Maximum of 4 elbows 45 or...

Страница 23: ...C D E F G H 302 348 345 55 5 90 40 20 200 250 150 200 I J K L M N O P 13 20 120 60 105 75 45 112 MODELS H mm G mm Double Vision Hot Box and all Heatseekers 150 200 Pure Vision Simplicity Elegance Sig...

Страница 24: ...24 AL DIMENSIONS Internal Power Flue Motor Internal Power Flue Motor 200 250 A B C D E F G H 268 281 331 311 202 152 300 128 A B C D E F G H 268 281 322 336 252 202 336 128...

Страница 25: ...t front of burner B The power polarity is reversed Check polarity B Sparker is to far from metal C Pressure switch Power Flue is not operating correctly Adjust sparker so it cross lights to metal Remo...

Страница 26: ...e a red LED light that indicates the possible cause of a problem the LED light will flash in different sequences for different problems the most common are Long Flash Short Flash 1 0 Normal Running St...

Страница 27: ...TE POWER FLUE CONTROL MODULE Heat Sensor Sparker Power Fan Pressure Switch Double Block Solenoid NOTE For C Bus and or fresh air damper interlock systems please contact us for wiring diagrams and rele...

Страница 28: ...Modular Box Part Number DUBM 241221 Sparker and Sensor Fitted to all Electronic Ignitions Part Number GST0829985 Techrite Electronic Ignition Module Part Number TAIS00RISD5 Techrite Power Flue Module...

Страница 29: ...SES AND FRONTS NOTE The marble base is used to access the main burner for service purposes therefore it should not be stuck down under any circumstances X Hybrid X Polished Note I J are for Hybrid ver...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...Fax 5229 0844 E mail realflamegeelong hotmail com au Sydney NSW Showroom 546 Pacific Highway Chatswood NSW 2067 Ph 02 8905 0189 Fax 02 8905 0192 E mail info realflame com au Miranda NSW Showroom 36 K...

Отзывы: