background image

REAL FLAME PTY LTD 

ABN 76 006 311 155

Head Office/Factory/Showroom

1340 Ferntree Gully Rd.

Scoresby Vic 3179

Ph: (03) 8706 2000  Fax: (03) 8706 2001

E-mail: [email protected]

Richmond - VIC Showroom

300 Swan St. 

Richmond Vic 3121

Ph: (03) 9428 4443  Fax: (03) 9428 4445

Dandenong - VIC Showroom

3/328 South Gippsland Highway, 

Dandenong South Vic 3164

Ph: (03) 9702 7853

E-mail: [email protected]

Geelong - VIC Showroom

1/2A Gordon Avenue.

Geelong West Vic 3218

Ph/Fax: 5229 0844

E-mail: [email protected]

Sydney - NSW Showroom

546 Pacific Highway.

Chatswood NSW 2067

Ph: (02) 8905 0189  Fax: (02) 8905 0192

E-mail: [email protected]

Miranda - NSW Showroom

36 Kareena Rd

Miranda NSW 2228

Ph: (02) 8513 6202  Fax: (02) 9520 1974

E-mail: [email protected]

Adelaide - SA Showroom

173 -175 Magill Rd.

Norwood SA 5067

Ph: (08) 8132 0371  Fax: (08) 8132 1687

E-mail: [email protected]

Miton - QLD Showroom

46 Douglas St, 

Milton QLD 4064

Ph: (07) 3368 2011

Perth – WA Showroom

47-53 McDonald St East,

Osborne Park WA 6017

Ph: (08) 9444 9900  Fax: (08) 9444 9800

Fyshwick – ACT Showroom

88 Wollongong St,

Fyshwick ACT 2609

Ph: (02) 6280 5522

Содержание Captiva 600

Страница 1: ...ACE HEATER INSTALLATION OPERATING MANUAL The Captiva 600 900 are approved to be installed as a zero clearance firebox and are designed to operate on Natural Gas and Propane LPG gases ONLY Approval Num...

Страница 2: ...has been installed in an outdoor setting 4 Limit of Liability The warranty provided under this warranty is limited to replacement or repair of the Real Flame Gas Burner only at our option To the exte...

Страница 3: ...smell may be apparent for the first few hours of use This is due to the heat resistant paint curing It is recommended to open windows in the room for the first lighting of the fire In some instances a...

Страница 4: ...nstallation 11 Vertical venting installation 13 Tests to be carried out by installer 14 Servicing and maintenance 14 Parts list 16 Gas control assembly 16 Flue termination cowls regulations 18 Remote...

Страница 5: ...Point Low Injector Size Gas Consumption 1 00 mm 15 Mj hr MODEL CAPTIVA 900 SERIAL NO DATE OF MANUFACTURE GAS TYPE APPROVAL GSCS20081 NATURAL GAS 1 00 kPa Test Pressure Point High Injector Size Gas Co...

Страница 6: ...ture which could cause burns of clothing ignition Young children should be carefully supervised when they are in the same room as the appliance Clothing or other flammable materials should not be plac...

Страница 7: ...the bottom and then lift the door up and remove from channel 7 CAPTIVA INSTALLATION PROCEDURE Figure 5 Remove box containing logset and unpack Place the large log at the rear of the firebox between t...

Страница 8: ...ure 11 Place remaining pebbles up the angle of the rear tray so as the tray is hidden Note Keep pebbles clear of burner rail 8 CAPTIVA INSTALLATION PROCEDURE Note If a coals only configuration is bein...

Страница 9: ...B C D E F G H I J K L FRONT 4 SIDED FRONT 3 SIDED B A C DIMENSIONS Captiva 600 A B C D E F G H 782 780 588 655 860 645 190 180 I J K L 385 140 85 120 Captiva 600 Trim A B C 790 930 840 9...

Страница 10: ...I J G H F C D B K L M E FRONT 4 SIDED FRONT 3 SIDED B A C DIMENSIONS Captiva 900 Captiva 900 Trim A B C 1020 930 840 A B C D E F G H 790 780 860 923 840 600 255 180 I J K L M 410 180 85 100 120 10...

Страница 11: ...5 865 790 655 930 100 60 120 85 120 65 900 785 860 410 750 835 1020 920 930 100 90 120 60 70 15 Flue Size Inner Outer 600 100mm 180mm 900 100mm 180mm Overall Dimensions in mm A Flange Bottom of 3 side...

Страница 12: ...d D dimensions as shown with framework included below fire to required height Ensure frame is suitable for fire weight Plasterboard to run beyond stud as shown and to go behind fixing flange on unit M...

Страница 13: ...d Flue termination will be located Flue terminations shall not be recessed in walls or sidings EXTREMELY IMPORTANT In heavy snow areas take extra care to prevent blocking flue termination with snow re...

Страница 14: ...AND MAINTENANCE To follow when servicing removing fan or changing valve or control modules IMPORTANT POWER MUST BE ISOLATED PRIOR TO CARRYING OUT THE SERVICE MAINENANCE SERVICE MAINENANCE ONLY TO BE...

Страница 15: ...er from front of burner and then gently remove burner taking care not to move the sparker sensor Figure 9 Remove front protection mesh by removing screws Figure 11 To remove control module firstly rem...

Страница 16: ...fan out the remote box must be removed and the burner tube is to be undone at the bulkhead Figure 14 Remove the burner to be nut either from the bulkhead or the brass elbow the valve can then be remo...

Страница 17: ...SEMBLY Inlet Test Pressure Point Outet Test Pressure Point Adjustment for High Adjustment for Low Gas Outlet Gas Inlet Gas Control Valve Module Box Remote Control Module Sparkers Sensor PARTS LIST Rem...

Страница 18: ...CAPTIVA FLUE TERMINATION COWLS REGULATIONS Balanced Flue 18...

Страница 19: ...n to turn the thermostat on and off Setting the day of the week and time With the thermostat off press and hold the T button for 2 seconds or longer to initiate programming the time Time the hour sett...

Страница 20: ...r Saturday Sunday The entire week can also have the same program Alternatively a weekday or weekend program can be set with individual programs for the remaining days The suggested period settings for...

Страница 21: ...ash Adjust the minute setting similarly using L or M button Press OK to accept Setting the temperature The temperature setting will now flash Press and release the L or M button to increase or decreas...

Страница 22: ...k like the diagram below once it has been installed and before mantelpiece has been attached 3 Refit trim over the marble Firebox A B C E D 200mm 200mm F X X X X X X X X X X X X Polished Only for boxe...

Страница 23: ...1840 1240 1140 900 60 80 240 600 BOX 1695 1240 750 820 20 320 430 900 BOX 1840 1240 980 820 20 320 430 MANTELPIECE DIMENSIONS Captiva Flush Captiva Boxed D B G C A E 200 x 200mm marble block Marble h...

Страница 24: ...l CON9 CON12 12 11 10 9 8 7 6 5 4 3 2 1 1 9 8 7 6 5 4 3 2 1 2 CON2 Reset Button Fuse 1 MO MO Ignitor High Speed Medium Speed Low Speed Neutral Neutral Neutral Active Low Med High TH1 TH2 MOD1 MOD2 FAN...

Страница 25: ...25...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...h Fax 5229 0844 E mail realflamegeelong hotmail com au Sydney NSW Showroom 546 Pacific Highway Chatswood NSW 2067 Ph 02 8905 0189 Fax 02 8905 0192 E mail info realflame com au Miranda NSW Showroom 36...

Отзывы: