background image

17

MEDIA INSTALLATION 

(continued)

Insert log 6

Insert log 7

Содержание ACCENT 800

Страница 1: ...T SPACE HEATER INSTALLATION OPERATING MANUAL The Real Flame Accent 800 space heater is suitable to be installed into a frame out installation Designed to operate on Natural gas and ULPG gas Approval n...

Страница 2: ...n outdoor setting 4 Limit of Liability The warranty provided under this warranty is limited to replacement or repair of the Gas Burner only at our option To the extent permitted by law Glen Dimplex ex...

Страница 3: ...ance shall meet the requirements as set out in AS NZS5601 1 2013 Do not install in a fireplace as a Type 1 installation NOTE A slight smell may be apparent for the first few hours of use This is due t...

Страница 4: ...Setup with external wall mounted fan terminal 9 Setup with rooftop termination 14 Timber Frame Installation 18 Media Installation 19 Commissioning Procedure 23 Operation User Instructions 24 Troubles...

Страница 5: ...reference to gas pressure consumption MODEL ACCENT 800 GAS TYPE Natural Gas 1 X 2 50mm 0 40kPa High 0 47kPa Low INJECTOR SIZE TPP N G C Mj hr 26 5 High 19 Low ULPG 1 X 1 38mm 2 60kPa High 1 60kPa Low...

Страница 6: ...as installation code AS NZS 5601 and applicable electrical installation code AS3000 Test for gas leaks prior to operating appliance Check gas pressures and adjust if incorrect WARNING Transit material...

Страница 7: ...flue terminals are very hot and must not be restricted to assure fireplace combustion is not affected Do not place build any obstruction plant any bushes or for any reason attempt to conceal the flue...

Страница 8: ...ACCENT 800 FLUE TERMINATION COWLS 8...

Страница 9: ...stalled with clearances as specified by AS NZS 5601 1 Clause 6 9 3 2 Run exhaust flue and air intake flue as required Maximum run 5m Flues can be run next to each other Maintain the required clearance...

Страница 10: ...nection spigot approx 10mm from the end Apply an 8mm silicon bead fully around the inside of the flue end heater connection end Fit flue clamp over flue loosely Slide flue onto connection spigot fully...

Страница 11: ...e exhaust tube hot tube to length Approximately flush with wall exit Wall termination will sit against wall Pull flue tube through approx 100mm further will be pushed back once terminal fitted Cut Air...

Страница 12: ...around the inside of the flue end heater connection end Slide flue onto connection spigot fully Tighten clamp fully Wipe excess silicon visually check connection to ensure connection is fully sealed F...

Страница 13: ...13 INSTALLATION INSTRUCTIONS continued Fit front cover...

Страница 14: ...TIMBER FRAME INSTALLATION 14 Plaster to run beyond stud and behind trim TRIM 2 x 84mm OD FLUES Indication only Can be smaller or larger A B A B C D 620 800 450 1500 Frameout Dimensions in mm C D...

Страница 15: ...xtra media or combine media types Only the approved supplied media is to be used Do not use any other media than as supplied and recommended by the manufacturer Use of other media may result in explos...

Страница 16: ...MEDIA INSTALLATION continued 16 Insert log 3 Insert log 4 Insert log 5...

Страница 17: ...17 MEDIA INSTALLATION continued Insert log 6 Insert log 7...

Страница 18: ...MEDIA INSTALLATION continued 18 Insert log 8 Finished assembly...

Страница 19: ...ue module loom to fan control unit Carry out the lighting procedure Check burner pressures and inlet supply pressure Valve is non adjustable Check appliance for combustion CO leakage Turn off Fit trim...

Страница 20: ...abnormal operation please contact your licensed gas installer gas service personnel or Real Flame Pty Ltd Abnormal operation may consist of the following noisy fan excessive or small flame unusual fla...

Страница 21: ...eries already installed in the transmitter push the On button The receiver will beep four times to indicate the transmitter s command is accepted and sets to the particular code of that transmitter Th...

Страница 22: ...t is pressed If the up arrow key is pressed while the system is on but the flame is off the flame will come on in the high position A single beep will confirm reception of the command Remote control d...

Страница 23: ...t is disabled Fan speed control this function is not supported on this fire Remote dimmer control Light this function is not supported on this fire Smart flame function Split flow control this functio...

Страница 24: ...ntrol batteries depends on various factors quality of the batteries used the number of ignitions of the appliance the number of changes to the room thermostat set point etc When the transmitter batter...

Страница 25: ...ively high Incorrect gas or pressure Check test point pressure and supply pressure to appliance Check gas type Replace valve if required Check injector for blockage and size Smell in room while operat...

Страница 26: ...on the receiver once three beeps should be heard 5 Press the on button on the remote four beeps should be heard 6 Remote is now connected If your fireplace still does not operate correctly consult you...

Страница 27: ...27 WIRING DIAGRAM...

Страница 28: ...on valve 15 Ensure all connections are tight 16 Connect gas and leak test connections upto the gas valve PILOT AND INJECTOR CHANGE 17 Remove firebox door 6 screws 18 Remove twig media from firebox 19...

Страница 29: ...29 PARTS LIST 1 Valve 2 SIT Pilot assembly 3 Injector 4 Burner 5 Remote control 6 Sit Ignition pack gas control 1 2 3 4 5 6...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...elong hotmail com au Sydney NSW Showroom 546 Pacific Highway Chatswood NSW 2067 Ph 02 8905 0189 Fax 02 8905 0192 E mail info realflame com au Miranda NSW Showroom 36 Kareena Rd Miranda NSW 2228 Ph 02...