Real Fires Electronic Range User Guide & Service Manual
10
Recheck burner pressure:
• Connect a manometer to the burner pressure test point.
• Reconnect the power and start the fire.
• Using the remote control, adjust the burner pressure to its maximum and
check the pressure against the data plate.
• Adjustment of the burner pressure is done using the nut and screw shown
on the diagram on page 11. Take care not to turn the low pressure set
screw when adjusting the high pressure and vice versa.
• Adjust the burner pressure to its lowest setting and check against the data
plate. Recheck the high pressure set again.
• Check the look of the flames when the fire has warmed up a little and
move any Logs/Coals that appear to be causing long, streaky flames.
• Turn the fire off, and remove the manometer.
• Check the test point for leaks.
• Replace the Front Panel, reflectors and side trim. Take care not to scratch
the hearth when refitting the outer trim.
• Re-test all functions of the Remote Control (burner high and low, fan high
and low, on and off).
Wiring Diagram
PILOT
ACTIVE
YL
GR
CONTROL BOX
(Millennium)
GAS CONTROL 12-PIN PLUG
FUSE
3 AMP
BRN
COLOUR
WH
WHITE
BLK
BLACK
YL
YELLOW
RD
RED
BLU
BLUE
BRN
BROWN
GR
GREEN / YELLOW
OR
ORANGE
4
3
2
1
BL
U
BL
U
MAINS IN
230/240 V a.c.
50 Hz
10 AMP
ME
D
LO
W
HIGH
MOD
2
NEUTRA
L
NEUTRA
L
MOD
1
YL
BLU
RD
WH
GR
BR
N
CAT 5 CABLE
TO RECEIVER
RD
WH
2 1
BR
N
BL
U
12
1
13/14
2 - EMPT
Y
5 - BL
K
1 - EMPT
Y
4 - EMPT
Y
6 - BL
K
7 - BL
K
8 - EMPT
Y
9 - EMPT
Y
10 - BR
N
11 - BL
U
12 - GR
3 - EMPT
Y
SPARK
FLAME
SPARK
GAS CONTROL
(SIT845 with 0.579.506 DBC)
WH (HT LEAD)
GR
OR
13 14