6.
Command Reference
This section describes the commands available. For typical command sequences, see
Appendix B.
When the unit is ready for a command, it issues the prompt
"RT-PoE3N>"
. Command
buffering is not supported; you must wait for the prompt before sending a command. The
prompt may be changed via the "hostname" command. The default baud rate is 9600. This
can be changed via the "baud" command.
All commands are terminated by a <return> which is the character 0x0D (decimal 13).
Most commands have a short form version. The optional characters of a command are
indicated by the [ ] brackets.
All commands that take "on" or "off" arguments can also take "1" and "0" as arguments.
Responses from the unit that include variable data such as the port number are shown as 'C'
printf style strings, so the script writer knows exactly what to expect as a response.
HELP
Description
Displays available commands.
Command:
he[lp]
Command:
?
Example:
help
VERSION
Description
Displays software and hardware version
Command:
vers[ion]
Result:
"
Reach PoE Tester Model RT-PoE3NL/8 Rev A HW 1.0
SW 1.02/1 02/08/2011 \r\n"
The
X
indicated the version of software on the line cards. An error is
generated if the line card versions are inconsistent.